LII:Radiation Oncology/Simulation devices
From LIMSWiki
Jump to navigationJump to searchThe printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.
|
Patient immobilization devices
[edit | edit source]- BOHAP - Blue OverHead Arm Positioner
- Karolinska Hospital (Sweden)(1998-2001) -- head mask vs head-and-neck mask setup
- Randomized. 241/260 patients. H&N cancers excluding NPC. Arm 1) Head mask vs. Arm 2) Head-and-shoulder mask. Both Posicast thermoplastic masks. Assessed reproducibility (port films and table positions), patient tolerability (fit, pain, movement within, claustrophobia), and skin damage
- 2005 PMID 15629618 -- "Randomized trial on two types of thermoplastic masks for patient immobilization during radiation therapy for head-and-neck cancer." (Sharp L, Int J Radiat Oncol Biol Phys. 2005 Jan 1;61(1):250-6.)
- Outcome: No difference in reproducibility of setup
- Toxicity: Claustrophobia head mask 45% vs. head-and-shoulder masks 58% (SS), otherwise no difference in tolerability. Skin toxicity Grade 3 head mask 21% vs. head-and-shoulder mask 39% (SS)
- Conclusion: Smaller head masks reduced claustrophobial and skin reactions, without compromising reproducibility of the setup
External links
[edit | edit source]Other:
- Medtec - Radiation detector (doesn't have anything to do with simulation)
Notes
This article is a direct transclusion of the Wikibooks article and therefore may not meet the same editing standards as LIMSwiki.