The central sterile services department (CSSD), also called sterile processing department (SPD), sterile processing, central supply department (CSD), or central supply, is an integrated place in hospitals and other health care facilities that performs sterilization and other actions on medical devices, equipment and consumables; for subsequent use by health workers in the operating theatre of the hospital and also for other aseptic procedures, e.g. catheterization, wound stitching and bandaging in a medical, surgical, maternity or paediatric ward.[1]

Background

The operations of a sterile services department usually consist of the cleaning, disinfection, and sterilization of reusable medical equipment. Reusable medical equipment, or RME, can consist of any medical equipment from stainless steel surgical instrumentation, to IV pumps and crash carts. RME is separated into three classes: non-critical, semi-critical, and critical, with each class requiring a minimum level of reprocessing.[2]

Non-critical items, such as IV poles and pumps, require a minimum of intermediate level disinfection which can be accomplished with most hospital disinfectants.[2]

Semi-critical items are items that are expected to have contact with what an intact mucous membrane, and normally consists of endoscopes like those used in colonoscopies.

These items require high level disinfectants such as glutaraldehyde solution, peracetic acid, or hydrogen peroxide plasma.[2]

Critical items, which include any instrument which will be introduced into a patient blood stream or in a normally sterile area of the body, require sterilization.[2]

Sterilization methods in use

Sterilization is the process of destroying all living organisms on an item and is the main task of most sterile services departments. Items to be sterilized must first be cleaned in a separate decontamination room and inspected for effectiveness, cleanliness and damage. There are multiple methods of sterilization, and which one is used is dependent on many factors including: operational cost, potential hazards to workers, efficacy, time, and composition of the materials being sterilized.[citation needed]

In the US, one of the cheapest and easiest methods is steam sterilization, where instrumentation trays and packages are placed in a chamber which is them filled with 250–270 °F (121–132 °C) steam, killing all microorganisms.[3]

Sterilization can also be achieved using ethylene oxide (ETO) gas. This process was created in the 1950s by the US military[4] and is used on items that cannot withstand the high temperatures of steam sterilization. ETO sterilization takes far longer than steam sterilization and is hazardous to workers, so alternative methods were created in the 1990s. The most common method for sterilizing at low temperatures today is by using hydrogen peroxide plasma, which has near zero risk to workers and cycles take a fraction of the time of ETO sterilization.[citation needed]

Depending on the healthcare facility's policy, there will be either an event related or time related sterile storage policy. If the policy is time related, an expiration date is placed on the sterile package, before being supplied to the end-user as a sterile product. If along the supply route, the sealed package got damaged or opened by a health worker, it needs to be returned to the CSSD for re-sterilization. If the healthcare facility's policy is event related, the package is considered sterile until an event occurs to compromise its sterility (e.g. opened, dropped package, high humidity conditions, etc.)[citation needed]

Decontamination is the most important step in the sterilization process beginning with point of use cleaning in the operating room. Items must be cleaned according to the manufacturer's instructions for use (IFU's). These must be followed for each item processed. Failure to properly clean a device will prevent sterilization from occurring. There are several factors that contribute to having a properly functioning decontamination area: [1] there must be proper dilution of detergents or damage to instruments will occur to include rusting and discoloration, [2] lumens are a big issue so there must be an assortment of brushes with varying lengths and diameters to thoroughly clean inside lumened instruments, [3] SPD staff need to be competent in the use of all processing equipment, [4] monthly in-service should be recurring and completed by the manufacturer's representative, [5] efficacy testing of the equipment should be completed and documented ensuring equipment is functioning as intended.[5]

Sterile processing technician

A sterile processing technician is someone who cleans and sterilizes used surgical instruments and other medical supplies so that they can be safely redistributed and reused on future patients. This work is usually centralized in a special department of the medical facility. Job titles include the following:[citation needed]

  • Sterile processing and distribution technician (SPD tech or CPD tech)
  • Central sterile supply technician (CSS tech)
  • Central processing technician (CPT)
  • Central service technician (CST)
  • Certified Sterile Science Technician (CSST)
  • Sterile Science Associate (SSA) - degree
  • Sterile Scientist (SS)- degree
  • Master of Sterile Sciences (MSS) - degree
  • Operation Theatre Technology (OTT)- degree/diploma

Divisions

Sterile processing departments are typically divided into four major areas to accomplish the functions of decontamination, assembly and sterile processing, sterile storage, and distribution.[6][7]

Decontamination

  • Disassembly & decontaminating used surgical instruments and other medical devices
  • Operating and maintaining special decontamination equipment like automatic washers/disinfectants, ultrasonic cleaners
  • Inspecting decontaminated items to make sure they are clean
  • Assembly
  • Utilize PPE's to protect self from acquiring harmful microorganisms

Sterilization and storage

  • Assembly & wrapping of cleaned and decontaminated instruments
  • Sterilizing assembled trays of instruments in appropriate sterilizers
  • Precisely operating and monitoring special sterilization equipment like autoclaves
  • Keeping detailed records of number of sterilized items, including Autoclave cycle numbers, lot/batch numbers, expiration dates for future tracking of items that has been sterilized, and stored

Distribution

  • Stocking crash carts
  • Organizing sterilized medical supplies
  • Ensuring that sterile supplies do not become outdated / preventing event related sterility issues
  • Delivering sterile supplies where they are needed and picking up dirty ones

See also

References

  1. ^ "Sterilization basics". University of Rochester. Retrieved 16 June 2016.
  2. ^ a b c d Health, Center for Devices and Radiological. "Reprocessing of Reusable Medical Devices - What are Reusable Medical Devices?". www.fda.gov. Retrieved 2018-10-17.
  3. ^ Rutala, W. A.; Stiegel, M. M.; Sarubbi, F. A. (1982-06-01). "Decontamination of laboratory microbiological waste by steam sterilization". Appl. Environ. Microbiol. 43 (6): 1311–1316. doi:10.1128/aem.43.6.1311-1316.1982. ISSN 0099-2240. PMC 244233. PMID 7103486.
  4. ^ Reichert, Marimargaret; Young, Jack H. (1997). Sterilization Technology for the Health Care Facility. Jones & Bartlett Learning. ISBN 9780834208384.
  5. ^ "Safety in the Operating Room Begins with Sterile Processing". 14 August 2018. Retrieved 2019-01-17.
  6. ^ "Central sterile service department (CSSD) - Definition, Aim, Function and Activities, Advantages, Objectives and Functions, Planning, Basic Division, Equipment". BrainKart. Retrieved 2022-03-27.
  7. ^ "Examining Central Sterile Services Department's role in patient safety". Omnia Health Insights. 2019-12-11. Retrieved 2022-03-27.

Notes

This article is a direct transclusion of article and therefore may not meet the same editing standards as LIMSwiki.