Difference between revisions of "User:Shawndouglas/sandbox/sublevel8"
Shawndouglas (talk | contribs) |
Shawndouglas (talk | contribs) |
||
Line 109: | Line 109: | ||
[https://www.law.cornell.edu/cfr/text/42/493.1274 42 CFR Part 493.1274]<br /> | [https://www.law.cornell.edu/cfr/text/42/493.1274 42 CFR Part 493.1274]<br /> | ||
[https://www.law.cornell.edu/cfr/text/42/493.1283 42 CFR Part 493.1283]<br /> | [https://www.law.cornell.edu/cfr/text/42/493.1283 42 CFR Part 493.1283]<br /> | ||
[https://www.aavld.org/accreditation-requirements-page | [https://www.aavld.org/accreditation-requirements-page AAVLD Requirements for an AVMDL Sec. 5.8.2]<br /> | ||
[http://www.abft.org/files/ABFT_LAP_Standards_May_31_2013.pdf ABFT Accreditation Manual D-3]<br /> | [http://www.abft.org/files/ABFT_LAP_Standards_May_31_2013.pdf ABFT Accreditation Manual D-3]<br /> | ||
[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 C-1-12]<br /> | [https://www.astm.org/Standards/E1578.htm ASTM E1578-18 C-1-12]<br /> | ||
Line 135: | Line 135: | ||
[http://www.oecd.org/chemicalsafety/testing/oecdseriesonprinciplesofgoodlaboratorypracticeglpandcompliancemonitoring.htm OECD GLP Principles 6.1] | [http://www.oecd.org/chemicalsafety/testing/oecdseriesonprinciplesofgoodlaboratorypracticeglpandcompliancemonitoring.htm OECD GLP Principles 6.1] | ||
| style="background-color:white;" |The system shall provide a user-friendly means for acknowledging the physical reception of sample material in the laboratory, including date and time of reception. | | style="background-color:white;" |The system shall provide a user-friendly means for acknowledging the physical reception of sample material in the laboratory, including date and time of reception. | ||
|- | |||
| style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 C-1-14]<br />[https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.4.6] | |||
| style="background-color:white;" |The system shall allow for the comparison of received samples to the sampling requirements of the customer or laboratory in order to identify variances from those requirements. | |||
|- | |||
| style="padding:5px; width:500px;" | | |||
[https://www.aavld.org/accreditation-requirements-page AAVLD Requirements for an AVMDL Sec. 5.8.3]<br /> | |||
[https://www.astm.org/Standards/E1492.htm ASTM E1492-11 4.1.1.5]<br /> | |||
[https://www.astm.org/Standards/E1492.htm ASTM E1492-11 4.1.6]<br /> | |||
[https://www.astm.org/Standards/E1492.htm ASTM E1492-11 4.3.3.2]<br /> | |||
[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 C-1-15]<br /> | |||
[https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.4.13]<br /> | |||
[https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.11.8]<br /> | |||
[https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Sample Processing and Analysis Procedures for PDP 5.1.3–7]<br /> | |||
[https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Sampling Procedures for PDP 6.4.1.1.9] | |||
| style="background-color:white;" |The system should provide a means to document any undesirable or unexpected characteristics of a submitted sample. | |||
|- | |- | ||
|} | |} | ||
|} | |} |
Revision as of 17:01, 13 September 2019
This is sublevel1 of my sandbox, where I play with features and test MediaWiki code. If you wish to leave a comment for me, please see my discussion page instead. |
Sandbox begins below
1. Sample/Experiment Registration
|