Difference between revisions of "User:Shawndouglas/Sandbox"
From LIMSWiki
Jump to navigationJump to searchShawndouglas (talk | contribs) m (→1.4.9 Laboratory management: Reworded item J) |
Shawndouglas (talk | contribs) m (→1.4.5 Post-analysis and validation: Added new item B) |
||
Line 757: | Line 757: | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''b.''' | | style="padding:5px; width:500px;" |'''b.''' Can your system automatically reorder a test if results don't meet lab-defined criteria? | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''c.''' Does your system | | style="padding:5px; width:500px;" |'''c.''' Does your system read results from previously entered tests to calculate a final result and immediately display the calculated result? | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''d.''' Does your system allow | | style="padding:5px; width:500px;" |'''d.''' Does your system allow authorized users to review all analytical results, including pricing, spec violations, history or trend analysis by analyte, and comments? | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''e.''' Does your system | | style="padding:5px; width:500px;" |'''e.''' Does your system allow on-screen review of the stored test result, diluted result with corrected method detection limits (MDLs), and qualifiers after running samples for multiple dilutions as in [[gas chromatography–mass spectrometry]] (GC-MS)? | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''f.''' Does your system | | style="padding:5px; width:500px;" |'''f.''' Does your system display the standard operating procedure (SOP) associated with each test result to ensure proper techniques were used? | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''g.''' Does your system | | style="padding:5px; width:500px;" |'''g.''' Does your system store test-related analysis comments with the test? | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''h.''' Does your system provide for | | style="padding:5px; width:500px;" |'''h.''' Does your system provide auto-commenting for common laboratory result comments? | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''i.''' Does your system | | style="padding:5px; width:500px;" |'''i.''' Does your system provide for high-volume multi-component transfers of test results, with the ability to automatically match samples to data files in either a backlog mode or a designated file mode, to parse the data, and to review and commit the sample data? | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''j.''' Does your system's results validation process | | style="padding:5px; width:500px;" |'''j.''' Does your system's results [[LIMS feature#Data validation|validation process]] access all information about a sample or group of samples, including comments or special information about the sample? | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''k.''' Does your system | | style="padding:5px; width:500px;" |'''k.''' Does your system's results validation process check each result against its individual sample location specifications (both warning and specification limits)? | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''l.''' Does your system | | style="padding:5px; width:500px;" |'''l.''' Does your system support validation at the analysis and sample level, while also prohibiting sample validation when analysis validation is incomplete? | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''m.''' Does your system | | style="padding:5px; width:500px;" |'''m.''' Does your system use a menu-driven process for results validation? | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''n.''' | | style="padding:5px; width:500px;" |'''n.''' Does your system provide secure electronic peer review of results? | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''o.''' | | style="padding:5px; width:500px;" |'''o.''' Can your system clearly differentiate released preliminary data from fully validated results? | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''p.''' Does your system | | style="padding:5px; width:500px;" |'''p.''' Does your system validate/approve data prior to being moved to the main database? | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''q.''' Does your system | | style="padding:5px; width:500px;" |'''q.''' Does your system fully manage all aspects of laboratory [[LIMS feature#QA/QC functions|quality control]], including the reporting and charting of all quality control data captured in the lab? Please explain how. | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''r.''' Does your system | | style="padding:5px; width:500px;" |'''r.''' Does your system provide a base for a quality assurance program, including proficiency testing, scheduled maintenance of equipment, etc.? Please explain how. | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''s.''' Does your system | | style="padding:5px; width:500px;" |'''s.''' Does your system distinguish QA/QC duplicates from normal samples? | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''t.''' Does your system allow | | style="padding:5px; width:500px;" |'''t.''' Does your system allow QA/QC tests to be easily created and associated with the primary analytical test? | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''u.''' Does your system | | style="padding:5px; width:500px;" |'''u.''' Does your system allow manual entry of QA and QC data not captured as part of the system's regular processes? | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''v.''' Does your system | | style="padding:5px; width:500px;" |'''v.''' Does your system calculate monthly QA/QC percentages for testing? | ||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
| style="padding:5px; width:500px;" |'''w.''' Does your system check data files for specification and corrects them for specific reporting and analyte limits and qualifiers like dilution factor, automatically assigning qualifiers based on project analyte limiting? | | style="padding:5px; width:500px;" |'''w.''' Does your system automatically flag out-of-range quality control limits? | ||
| style="background-color:white; padding:5px;" | | |||
| style="background-color:white;" | | |||
|- | |||
| style="padding:5px; width:500px;" |'''x.''' Does your system check data files for specification and corrects them for specific reporting and analyte limits and qualifiers like dilution factor, automatically assigning qualifiers based on project analyte limiting? | |||
| style="background-color:white; padding:5px;" | | | style="background-color:white; padding:5px;" | | ||
| style="background-color:white;" | | | style="background-color:white;" | | ||
|- | |- | ||
|} | |} | ||
===1.4.6 Instruments=== | ===1.4.6 Instruments=== | ||
{| class="wikitable collapsible" border="1" cellpadding="10" cellspacing="0" | {| class="wikitable collapsible" border="1" cellpadding="10" cellspacing="0" |
Revision as of 18:33, 1 August 2014
This is my sandbox, where I play with features and test MediaWiki code. If you wish to leave a comment for me, please see my discussion page instead. |
Sandbox begins below
1.0 Vendor information
|
1.1 Vendor services
|
1.2 Information technology
1.2.1 General IT
1.2.2 Hardware environment
1.2.3 Software environment
|
1.3 Regulatory compliance and security
1.3.1 Regulatory compliance
1.3.2 Security
|
1.4 General system functions
1.4.1 General functions
1.4.2 Configuration and customization
1.4.3 Receiving and scheduling
1.4.4 Analysis and data entry
1.4.5 Post-analysis and validation
1.4.6 Instruments
1.4.7 External system interfaces
1.4.8 Reporting
1.4.9 Laboratory management
|
1.5 System-specific
The system-specific addendum can be found here.
1.6 Industry-specific
The industry-specific addendum can be found here.
1.7 Custom requirements
|