Line 51: | Line 51: | ||
[https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.9.5 and 4.9.14]<br /> | [https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.9.5 and 4.9.14]<br /> | ||
[https://www.iso.org/standard/66912.html ISO/IEC 17025:2017 8.4.2]<br /> | [https://www.iso.org/standard/66912.html ISO/IEC 17025:2017 8.4.2]<br /> | ||
[https://www.wadsworth.org/regulatory/clep/clinical-labs/laboratory-standards NYSDOH CLEP Clinical Laboratory Standards of Practice, General Systems Standards]<br /> | |||
[https://www.oecd.org/chemicalsafety/testing/oecdseriesonprinciplesofgoodlaboratorypracticeglpandcompliancemonitoring.htm OECD GLP Principles 3.4]<br /> | [https://www.oecd.org/chemicalsafety/testing/oecdseriesonprinciplesofgoodlaboratorypracticeglpandcompliancemonitoring.htm OECD GLP Principles 3.4]<br /> | ||
[https://www.oecd.org/chemicalsafety/testing/oecdseriesonprinciplesofgoodlaboratorypracticeglpandcompliancemonitoring.htm OECD GLP Principles 10]<br /> | [https://www.oecd.org/chemicalsafety/testing/oecdseriesonprinciplesofgoodlaboratorypracticeglpandcompliancemonitoring.htm OECD GLP Principles 10]<br /> | ||
Line 75: | Line 76: | ||
| style="background-color:white;" |'''27.5''' The system should feature a reliable, effective, and supported data storage system. | | style="background-color:white;" |'''27.5''' The system should feature a reliable, effective, and supported data storage system. | ||
|- | |- | ||
| style="padding:5px; width:500px;" |[https://www.astm.org/e1578-18.html ASTM E1578-18 C-6-6]<br />[https://www.astm.org/e1578-18.html ASTM E1578-18 E-13-6]<br />[https://clsi.org/standards/products/quality-management-systems/documents/qms22/ CLSI QMS22 2.2.3.3] | | style="padding:5px; width:500px;" | | ||
[https://www.astm.org/e1578-18.html ASTM E1578-18 C-6-6]<br /> | |||
[https://www.astm.org/e1578-18.html ASTM E1578-18 E-13-6]<br /> | |||
[https://clsi.org/standards/products/quality-management-systems/documents/qms22/ CLSI QMS22 2.2.3.3]<br /> | |||
[https://www.wadsworth.org/regulatory/clep/clinical-labs/laboratory-standards NYSDOH CLEP Clinical Laboratory Standards of Practice, General Systems Standards] | |||
| style="background-color:white;" |'''27.6''' The system should be able to interface directly with a third-party reporting tool. | | style="background-color:white;" |'''27.6''' The system should be able to interface directly with a third-party reporting tool. | ||
|- | |- | ||
Line 113: | Line 118: | ||
[https://www.iso.org/standard/66912.html ISO/IEC 17025:2017 8.4.2]<br /> | [https://www.iso.org/standard/66912.html ISO/IEC 17025:2017 8.4.2]<br /> | ||
[https://csrc.nist.gov/publications/detail/sp/800-53/rev-5/final NIST 800-53, Rev. 5, CP-9 and CP-10]<br /> | [https://csrc.nist.gov/publications/detail/sp/800-53/rev-5/final NIST 800-53, Rev. 5, CP-9 and CP-10]<br /> | ||
[https://www.wadsworth.org/regulatory/clep/clinical-labs/laboratory-standards NYSDOH CLEP Clinical Laboratory Standards of Practice, General Systems Standards]<br /> | |||
[https://www.who.int/medicines/areas/quality_safety/quality_assurance/expert_committee/trs_986/en/ WHO Technical Report Series, #986, Annex 2, 15.9] | [https://www.who.int/medicines/areas/quality_safety/quality_assurance/expert_committee/trs_986/en/ WHO Technical Report Series, #986, Annex 2, 15.9] | ||
| style="background-color:white;" |'''27.11''' The system’s data storage tools shall provide data backup and retrieval functions that meet or exceed industry best practices, including producing exact and complete backups that are secure from manipulation and loss. | | style="background-color:white;" |'''27.11''' The system’s data storage tools shall provide data backup and retrieval functions that meet or exceed industry best practices, including producing exact and complete backups that are secure from manipulation and loss. | ||
Line 283: | Line 289: | ||
[https://www.iso.org/standard/66912.html ISO/IEC 17025:2017 6.3.4]<br /> | [https://www.iso.org/standard/66912.html ISO/IEC 17025:2017 6.3.4]<br /> | ||
[https://www.iso.org/standard/66912.html ISO/IEC 17025:2017 7.4.4]<br /> | [https://www.iso.org/standard/66912.html ISO/IEC 17025:2017 7.4.4]<br /> | ||
[https://www.wadsworth.org/regulatory/clep/clinical-labs/laboratory-standards NYSDOH CLEP Clinical Laboratory Standards of Practice, General Systems Standards]<br /> | |||
[https://www.oecd.org/chemicalsafety/testing/oecdseriesonprinciplesofgoodlaboratorypracticeglpandcompliancemonitoring.htm OECD GLP Principles 10]<br /> | [https://www.oecd.org/chemicalsafety/testing/oecdseriesonprinciplesofgoodlaboratorypracticeglpandcompliancemonitoring.htm OECD GLP Principles 10]<br /> | ||
[https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Sample Processing and Analysis Procedures for PDP 5.2]<br /> | [https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Sample Processing and Analysis Procedures for PDP 5.2]<br /> |