[https://www.law.cornell.edu/cfr/text/45/170.315 45 CFR Part 170.315 (d-5)]<br /> | [https://www.law.cornell.edu/cfr/text/45/170.315 45 CFR Part 170.315 (d-5)]<br /> | ||
[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 S-3-1]<br /> | [https://www.astm.org/Standards/E1578.htm ASTM E1578-18 S-3-1]<br /> | ||
[https://www.fbi.gov/services/cjis/cjis-security-policy-resource-center CJIS Security Policy 5.5.5] | [https://www.fbi.gov/services/cjis/cjis-security-policy-resource-center CJIS Security Policy 5.5.5]<br /> | ||
[https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53r4.pdf NIST 800-53, Rev. 4, AC-11] | |||
| style="background-color:white;" |'''34.1''' The system shall provide administrators with a configurable period of time to apply to user access or inactivity before again prompting a user for authentication credentials. | | style="background-color:white;" |'''34.1''' The system shall provide administrators with a configurable period of time to apply to user access or inactivity before again prompting a user for authentication credentials. | ||
|- | |- | ||
Line 38: | Line 39: | ||
[https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.1.14–15]<br /> | [https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.1.14–15]<br /> | ||
[https://www.iso.org/standard/56115.html ISO 15189:2012 5.10.2]<br /> | [https://www.iso.org/standard/56115.html ISO 15189:2012 5.10.2]<br /> | ||
[https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53r4.pdf NIST 800-53, Rev. 4, AC-2(7) and AC-3]<br /> | |||
[https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53r4.pdf NIST 800-53, Rev. 4, IA-2 and IA-8]<br /> | |||
[https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53r4.pdf NIST 800-53, Rev. 4, MA-4]<br /> | |||
[https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53r4.pdf NIST 800-53, Rev. 4, PS-4 and PS-5]<br /> | |||
[https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Administrative Procedures for the PDP 5.2.4]<br /> | [https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Administrative Procedures for the PDP 5.2.4]<br /> | ||
[https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Administrative Procedures for the PDP 5.5.1.2] | [https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Administrative Procedures for the PDP 5.5.1.2] | ||
Line 45: | Line 50: | ||
| style="background-color:white;" |'''34.5''' The vendor should provide maintenance agreements and support services for its applications and services. | | style="background-color:white;" |'''34.5''' The vendor should provide maintenance agreements and support services for its applications and services. | ||
|- | |- | ||
| style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 S-3-9]<br />[https://ec.europa.eu/health/sites/health/files/files/eudralex/vol-4/annex11_01-2011_en.pdf E.U. Annex 11-3.3]<br />[https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Administrative Procedures for the PDP 5.2.4] | | style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 S-3-9]<br /> | ||
[https://ec.europa.eu/health/sites/health/files/files/eudralex/vol-4/annex11_01-2011_en.pdf E.U. Annex 11-3.3]<br /> | |||
[https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53r4.pdf NIST 800-53, Rev. 4, SA-16]<br /> | |||
[https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Administrative Procedures for the PDP 5.2.4] | |||
| style="background-color:white;" |'''34.6''' The vendor shall provide help desk, training, and installation support, as well as high-quality system documentation. The documentation should be reviewed to ensure that user requirements are fulfilled. | | style="background-color:white;" |'''34.6''' The vendor shall provide help desk, training, and installation support, as well as high-quality system documentation. The documentation should be reviewed to ensure that user requirements are fulfilled. | ||
|- | |- | ||
Line 65: | Line 73: | ||
[https://www.iso.org/standard/56115.html ISO 15189:2012 5.10.2]<br /> | [https://www.iso.org/standard/56115.html ISO 15189:2012 5.10.2]<br /> | ||
[https://www.iso.org/standard/66912.html ISO/IEC 17025:2017 7.11.3]<br /> | [https://www.iso.org/standard/66912.html ISO/IEC 17025:2017 7.11.3]<br /> | ||
[https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53r4.pdf NIST 800-53, Rev. 4, MA-5]<br /> | |||
[https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53r4.pdf NIST 800-53, Rev. 4, MP-2]<br /> | |||
[https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53r4.pdf NIST 800-53, Rev. 4, PE-3, PE-3(1), PE-6, PE-6(1), and PE-6(4)]<br /> | |||
[https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Administrative Procedures for the PDP 5.2.1] | [https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Administrative Procedures for the PDP 5.2.1] | ||
| style="background-color:white;" |'''34.7''' The vendor shall restrict logical access to database storage components to authorized individuals. If providing a hosted service, the vendor should also restrict physical access to database storage components to authorized individuals. (In the case of an on-site solution, the buyer is responsible for limiting physical access to database storage components to meet 21 CFR Part 11, HIPAA, and CJIS guidelines.) | | style="background-color:white;" |'''34.7''' The vendor shall restrict logical access to database storage components to authorized individuals. If providing a hosted service, the vendor should also restrict physical access to database storage components to authorized individuals. (In the case of an on-site solution, the buyer is responsible for limiting physical access to database storage components to meet 21 CFR Part 11, HIPAA, and CJIS guidelines.) | ||
Line 84: | Line 95: | ||
[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 S-3-11]<br /> | [https://www.astm.org/Standards/E1578.htm ASTM E1578-18 S-3-11]<br /> | ||
[https://www.fbi.gov/services/cjis/cjis-security-policy-resource-center CJIS Security Policy 5.10.4.1]<br /> | [https://www.fbi.gov/services/cjis/cjis-security-policy-resource-center CJIS Security Policy 5.10.4.1]<br /> | ||
[https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.9.13] | [https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.9.13]<br /> | ||
[https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53r4.pdf NIST 800-53, Rev. 4, SI-2(5)] | |||
| style="background-color:white;" |'''34.10''' The vendor should provide timely upgrades and patches, with complete documentation, that have been tested before installation and can be rolled back. | | style="background-color:white;" |'''34.10''' The vendor should provide timely upgrades and patches, with complete documentation, that have been tested before installation and can be rolled back. | ||
|- | |- | ||
Line 99: | Line 111: | ||
| style="background-color:white;" |'''34.14''' The system should provide some sort of support for use on mobile technologies, particularly for the purpose of receiving notifications and monitoring processes. | | style="background-color:white;" |'''34.14''' The system should provide some sort of support for use on mobile technologies, particularly for the purpose of receiving notifications and monitoring processes. | ||
|- | |- | ||
| style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 S-3-15]<br />[https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.9.13] | | style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 S-3-15]<br /> | ||
[https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.9.13]<br /> | |||
[https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53r4.pdf NIST 800-53, Rev. 4, CM-3(2)]<br /> | |||
[https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53r4.pdf NIST 800-53, Rev. 4, SI-2] | |||
| style="background-color:white;" |'''34.15''' The system shall be able to install an upgrade into a test environment for testing purposes before upgrading the actual production environment. | | style="background-color:white;" |'''34.15''' The system shall be able to install an upgrade into a test environment for testing purposes before upgrading the actual production environment. | ||
|- | |- | ||
|} | |} | ||
|} | |} |
Revision as of 21:35, 15 November 2019
|