Difference between revisions of "User:Shawndouglas/sandbox/sublevel11"
Shawndouglas (talk | contribs) |
Shawndouglas (talk | contribs) |
||
Line 233: | Line 233: | ||
| style="background-color:white;" |The system shall allow the creation, approval, rejection, and management of sampling and test methods performed at the laboratory, capturing details about the test method, method reference, specifications, assigned limits, holding times, etc. as required by a reference method or regulation. | | style="background-color:white;" |The system shall allow the creation, approval, rejection, and management of sampling and test methods performed at the laboratory, capturing details about the test method, method reference, specifications, assigned limits, holding times, etc. as required by a reference method or regulation. | ||
|- | |- | ||
| | | style="padding:5px; width:500px;" | | ||
| | [https://www.law.cornell.edu/cfr/text/21/212.20 21 CFR Part 212.20 (c)]<br /> | ||
[https://www.law.cornell.edu/cfr/text/21/212.70 21 CFR Part 212.70 (b)]<br /> | |||
[https://www.aavld.org/accreditation-requirements-page AAVLD Requirements for an AVMDL Sec. 5.4.2.4]<br /> | |||
[http://www.abft.org/files/ABFT_LAP_Standards_May_31_2013.pdf ABFT Accreditation Manual Sec. G-12, -14, and -15]<br /> | |||
[http://des.wa.gov/sites/default/files/public/documents/About/1063/RFP/Add7_Item4ASCLD.pdf ASCLD/LAB Supp. Reqs. for the Accreditation of Forensic Science Testing Laboratories 5.4.5.4]<br /> | |||
[https://www.epa.gov/quality/guidance-quality-assurance-project-plans-epa-qag-5 EPA QA/G-5 2.2.4]<br /> | |||
[https://www.iso.org/standard/66912.html ISO/IEC 17025:2017 7.2.2.1]<br /> | |||
[https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Administrative Procedures for the PDP 8.4]<br /> | |||
[https://extranet.who.int/prequal/content/who-technical-report-series WHO Technical Report Series, #986, Annex 2, 4.11]<br /> | |||
[https://extranet.who.int/prequal/content/who-technical-report-series WHO Technical Report Series, #986, Annex 2, 15.13] | |||
| style="background-color:white;" |The system shall provide a means for recording validation information for modified existing or new in-house test methods, either as a method itself or through some other means. Validation information such as procedures used, specifications, performance characteristics, and results obtained shall be allowed as input. | |||
|- | |||
| style="padding:5px; width:500px;" | | |||
[https://www.law.cornell.edu/cfr/text/7/331.10 7 CFR Part 331.10]<br /> | |||
[https://www.law.cornell.edu/cfr/text/7/331.15 7 CFR Part 331.15]<br /> | |||
[https://www.law.cornell.edu/cfr/text/9/121.10 9 CFR Part 121.10 ]<br /> | |||
[https://www.law.cornell.edu/cfr/text/9/121.15 9 CFR Part 121.15 ]<br /> | |||
[https://www.law.cornell.edu/cfr/text/21/11.10 21 CFR Part 11.10 (i)]<br /> | |||
[https://www.law.cornell.edu/cfr/text/21/58.29 21 CFR Part 58.29]<br /> | |||
[https://www.law.cornell.edu/cfr/text/21/211.25 21 CFR Part 211.25]<br /> | |||
[https://www.law.cornell.edu/cfr/text/21/225.10 21 CFR Part 225.10]<br /> | |||
[https://www.law.cornell.edu/cfr/text/21/226.10 21 CFR Part 226.10]<br /> | |||
[https://www.law.cornell.edu/cfr/text/21/226.40 21 CFR Part 226.40]<br /> | |||
[https://www.law.cornell.edu/cfr/text/21/820.25 21 CFR Part 820.25]<br /> | |||
[https://www.law.cornell.edu/cfr/text/29/1910.134 29 CFR Part 1910.134 (c)]<br /> | |||
[https://www.law.cornell.edu/cfr/text/29/1910.1030 29 CFR Part 1910.1030 (g-2)]<br /> | |||
[https://www.law.cornell.edu/cfr/text/29/1910.1030 29 CFR Part 1910.1030 (h-2)]<br /> | |||
[https://www.law.cornell.edu/cfr/text/29/1910.1200 29 CFR Part 1910.1200 (h)]<br /> | |||
[https://www.law.cornell.edu/cfr/text/29/1910.1450 29 CFR Part 1910.1450 (f)]<br /> | |||
[https://www.law.cornell.edu/cfr/text/42/73.10 42 CFR Part 73.10]<br /> | |||
[https://www.law.cornell.edu/cfr/text/42/73.15 42 CFR Part 73.15]<br /> | |||
[https://www.law.cornell.edu/cfr/text/42/493.43 42 CFR Part 493.43 (c)]<br /> | |||
[https://www.law.cornell.edu/cfr/text/42/493.1235 42 CFR Part 493.1235]<br /> | |||
[https://www.law.cornell.edu/cfr/text/42/493.1251 42 CFR Part 493.1251]<br /> | |||
[https://www.law.cornell.edu/cfr/text/45/164.308 45 CFR Part 164.308]<br /> | |||
[https://www.law.cornell.edu/cfr/text/45/164.530 45 CFR Part 164.530]<br /> | |||
[https://www.aafco.org/Publications/QA-QC-Guidelines-for-Feed-Laboratories AAFCO QA/QC Guidelines for Feed Laboratories Sec. 1.4 and 1.6]<br /> | |||
[https://www.aavld.org/accreditation-requirements-page AAVLD Requirements for an AVMDL Sec. 5.2]<br /> | |||
[https://www.aavld.org/accreditation-requirements-page AAVLD Requirements for an AVMDL Sec. 5.4.2.2]<br /> | |||
[https://www.aavld.org/accreditation-requirements-page AAVLD Requirements for an AVMDL Appendix 1]<br /> | |||
[http://www.abft.org/files/ABFT_LAP_Standards_May_31_2013.pdf ABFT Accreditation Manual Sec. B]<br /> | |||
[https://www.aihaaccreditedlabs.org/Policies/Pages/default.aspx AIHA-LAP Policies 2018 (various parts)]<br /> | |||
[http://des.wa.gov/sites/default/files/public/documents/About/1063/RFP/Add7_Item4ASCLD.pdf ASCLD/LAB Supp. Reqs. for the Accreditation of Forensic Science Testing Laboratories 4.13.2.12]<br /> | |||
[http://des.wa.gov/sites/default/files/public/documents/About/1063/RFP/Add7_Item4ASCLD.pdf ASCLD/LAB Supp. Reqs. for the Accreditation of Forensic Science Testing Laboratories 5.2.1.1–3]<br /> | |||
[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 C-3-5]<br /> | |||
[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 D-1-6]<br /> | |||
[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 E-1-6]<br /> | |||
[https://ec.europa.eu/health/sites/health/files/files/eudralex/vol-4/annex11_01-2011_en.pdf E.U. Annex 11-2]<br /> | |||
[https://ec.europa.eu/health/sites/health/files/files/eudralex/vol-1/dir_2003_94/dir_2003_94_en.pdf E.U. Commission Directive 2003/94/EC Article 7.4]<br /> | |||
[https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=30006MXP.PDF EPA 815-R-05-004 Chap. III, Sec. 10 and 17]<br /> | |||
[https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=30006MXP.PDF EPA 815-R-05-004 Chap. IV, Sec. 1]<br /> | |||
[https://www.epa.gov/quality/guidance-quality-assurance-project-plans-epa-qag-5 EPA QA/G-5 2.1.8]<br /> | |||
[https://www.iso.org/standard/56115.html ISO 15189:2012 4.1.2.1]<br /> | |||
[https://www.iso.org/standard/56115.html ISO 15189:2012 5.1.6]<br /> | |||
[https://www.iso.org/standard/56115.html ISO 15189:2012 5.1.9]<br /> | |||
[https://www.iso.org/standard/66912.html ISO/IEC 17025:2017 6.2.2]<br /> | |||
[https://www.iso.org/standard/66912.html ISO/IEC 17025:2017 6.2.3]<br /> | |||
[https://www.iso.org/standard/66912.html ISO/IEC 17025:2017 6.2.5]<br /> | |||
[https://www.iso.org/standard/66912.html ISO/IEC 17025:2017 6.2.6]<br /> | |||
[http://www.oecd.org/chemicalsafety/testing/oecdseriesonprinciplesofgoodlaboratorypracticeglpandcompliancemonitoring.htm OECD GLP Principles 1.1.2]<br /> | |||
[https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Administrative Procedures for the PDP 6.1]<br /> | |||
| style="background-color:white;" |The system shall maintain training and certification records for personnel and allow the assignment of available training paths and certifications to specific personnel, such that only trained, certified, and experienced personnel are able to perform assigned tasks. | |||
|- | |||
|} | |} | ||
|} | |} |
Revision as of 22:55, 13 September 2019
This is sublevel2 of my sandbox, where I play with features and test MediaWiki code. If you wish to leave a comment for me, please see my discussion page instead. |
Sandbox begins below
6. Reporting
|