Difference between revisions of "Template:LIMSpec/Configuration management"
Shawndouglas (talk | contribs) m (Spacing issues) |
Shawndouglas (talk | contribs) m (Tweaks) |
||
(2 intermediate revisions by the same user not shown) | |||
Line 31: | Line 31: | ||
[https://www.acmg.net/ACMG/Medical-Genetics-Practice-Resources/Genetics_Lab_Standards/ACMG/Medical-Genetics-Practice-Resources/Genetics_Lab_Standards.aspx ACMG Technical Standards for Clinical Genetics Laboratories C13.3]<br /> | [https://www.acmg.net/ACMG/Medical-Genetics-Practice-Resources/Genetics_Lab_Standards/ACMG/Medical-Genetics-Practice-Resources/Genetics_Lab_Standards.aspx ACMG Technical Standards for Clinical Genetics Laboratories C13.3]<br /> | ||
[https://www.astm.org/e1578-18.html ASTM E1578-18 S-1-5]<br /> | [https://www.astm.org/e1578-18.html ASTM E1578-18 S-1-5]<br /> | ||
[https://csrc.nist.gov/publications/detail/sp/800-53/rev-5/final NIST 800-53, Rev. 5, AU-10]<br /> | |||
[https://www.gmp-compliance.org/guidelines/gmp-guideline/who-guidance-on-good-data-and-record-management-practices WHO Technical Report Series, #996, Annex 5, Appendix 1] | [https://www.gmp-compliance.org/guidelines/gmp-guideline/who-guidance-on-good-data-and-record-management-practices WHO Technical Report Series, #996, Annex 5, Appendix 1] | ||
| style="background-color:white;" |'''32.7''' The system should provide a configurable (based on sample, test, or both) means of permitting electronic signatures for both entered results and approved reports. | | style="background-color:white;" |'''32.7''' The system should provide a configurable (based on sample, test, or both) means of permitting electronic signatures for both entered results and approved reports. | ||
Line 77: | Line 78: | ||
| style="background-color:white;" |'''32.20''' The system should provide a multiuser interface that can be configured to local user needs, including display language, character sets, and time zones. | | style="background-color:white;" |'''32.20''' The system should provide a multiuser interface that can be configured to local user needs, including display language, character sets, and time zones. | ||
|- | |- | ||
| style="padding:5px; width:500px;" |[https://www.law.cornell.edu/cfr/text/21/11.100 21 CFR Part 11.100 (a)]<br />[https://www.astm.org/e1578-18.html ASTM E1578-18 S-1-20]<br />[https://ec.europa.eu/health/sites/health/files/files/eudralex/vol-4/annex11_01-2011_en.pdf E.U. Annex 11-14]<br />[https://csrc.nist.gov/publications/detail/sp/800-53/rev-5/final NIST 800-53, Rev. 5, CM-5(1)]<br />[https://www.gmp-compliance.org/guidelines/gmp-guideline/who-guidance-on-good-data-and-record-management-practices WHO Technical Report Series, #996, Annex 5, Appendix 1] | | style="padding:5px; width:500px;" | | ||
[https://www.law.cornell.edu/cfr/text/21/11.100 21 CFR Part 11.100 (a)]<br /> | |||
[https://www.astm.org/e1578-18.html ASTM E1578-18 S-1-20]<br /> | |||
[https://ec.europa.eu/health/sites/health/files/files/eudralex/vol-4/annex11_01-2011_en.pdf E.U. Annex 11-14]<br /> | |||
[https://csrc.nist.gov/publications/detail/sp/800-53/rev-5/final NIST 800-53, Rev. 5, CM-5(1)]<br /> | |||
[https://www.gmp-compliance.org/guidelines/gmp-guideline/who-guidance-on-good-data-and-record-management-practices WHO Technical Report Series, #996, Annex 5, Appendix 1] | |||
| style="background-color:white;" |'''32.21''' The system should support rules governing electronic records and electronic signatures in regulated environments. | | style="background-color:white;" |'''32.21''' The system should support rules governing electronic records and electronic signatures in regulated environments. | ||
|- | |- | ||
Line 168: | Line 174: | ||
| style="background-color:white;" |'''32.27''' The system shall allow the administrator to define a time period in days after which a user will be prompted to change their password. | | style="background-color:white;" |'''32.27''' The system shall allow the administrator to define a time period in days after which a user will be prompted to change their password. | ||
|- | |- | ||
| style="padding:5px; width:500px;" |[https://www.fbi.gov/services/cjis/cjis-security-policy-resource-center CJIS Security Policy 5.6.3.1]<br />[https://csrc.nist.gov/publications/detail/sp/800-53/rev-5/final NIST 800-53, Rev. 5, AC-2(3)]<br /> | | style="padding:5px; width:500px;" |[https://www.fbi.gov/services/cjis/cjis-security-policy-resource-center CJIS Security Policy 5.6.3.1]<br />[https://csrc.nist.gov/publications/detail/sp/800-53/rev-5/final NIST 800-53, Rev. 5, AC-2(3)]<br />[https://csrc.nist.gov/publications/detail/sp/800-53/rev-5/final NIST 800-53, Rev. 5, IA-4 and IA-5(1)]<br />[https://csrc.nist.gov/publications/detail/sp/800-53/rev-5/final NIST 800-53, Rev. 5, PS-4] | ||
[https://csrc.nist.gov/publications/detail/sp/800-53/rev-5/final NIST 800-53, Rev. 5, IA-4 and IA-5(1)]<br /> | |||
[https://csrc.nist.gov/publications/detail/sp/800-53/rev-5/final NIST 800-53, Rev. 5, PS-4] | |||
| style="background-color:white;" |'''32.28''' The system shall allow the administrator to define a time period of inactivity for a user identifier, after which it will be disabled and archived. | | style="background-color:white;" |'''32.28''' The system shall allow the administrator to define a time period of inactivity for a user identifier, after which it will be disabled and archived. | ||
|- | |- | ||
Line 244: | Line 248: | ||
[https://www.astm.org/e1578-18.html ASTM E1578-18 S-1-24]<br /> | [https://www.astm.org/e1578-18.html ASTM E1578-18 S-1-24]<br /> | ||
[https://ec.europa.eu/health/sites/health/files/files/eudralex/vol-4/annex11_01-2011_en.pdf E.U. Annex 11-14]<br /> | [https://ec.europa.eu/health/sites/health/files/files/eudralex/vol-4/annex11_01-2011_en.pdf E.U. Annex 11-14]<br /> | ||
[https://csrc.nist.gov/publications/detail/sp/800-53/rev-5/final NIST 800-53, Rev. 5, AU-10 and AU-10(3)]<br /> | |||
[https://www.gmp-compliance.org/guidelines/gmp-guideline/who-guidance-on-good-data-and-record-management-practices WHO Technical Report Series, #996, Annex 5, Appendix 1] | [https://www.gmp-compliance.org/guidelines/gmp-guideline/who-guidance-on-good-data-and-record-management-practices WHO Technical Report Series, #996, Annex 5, Appendix 1] | ||
| style="background-color:white;" |'''32.36''' The system shall force a user's electronic signature to be unique and traceable to a specific user's account. | | style="background-color:white;" |'''32.36''' The system shall force a user's electronic signature to be unique and traceable to a specific user's account. | ||
|- | |- | ||
| style="padding:5px; width:500px;" |[https://www.law.cornell.edu/cfr/text/21/11.100 21 CFR Part 11.100 (a)]<br />[https://www.astm.org/e1578-18.html ASTM E1578-18 S-1-24]<br /> | | style="padding:5px; width:500px;" |[https://www.law.cornell.edu/cfr/text/21/11.100 21 CFR Part 11.100 (a)]<br />[https://www.astm.org/e1578-18.html ASTM E1578-18 S-1-24]<br />[https://csrc.nist.gov/publications/detail/sp/800-53/rev-5/final NIST 800-53, Rev. 5, AU-10 and AU-10(3)] | ||
| style="background-color:white;" |'''32.37''' The system shall prevent the reuse or reassignment of a user's electronic signature. | | style="background-color:white;" |'''32.37''' The system shall prevent the reuse or reassignment of a user's electronic signature. | ||
|- | |- |
Latest revision as of 14:29, 23 June 2023
|