Difference between revisions of "Template:LIMSpec/Sample and experiment registration"
From LIMSWiki
Jump to navigationJump to searchShawndouglas (talk | contribs) (Updated for food and bev update) |
Shawndouglas (talk | contribs) m (NIST tweak) |
||
(3 intermediate revisions by the same user not shown) | |||
Line 8: | Line 8: | ||
! style="color:brown; background-color:#ffffee; width:700px;"| Requirement | ! style="color:brown; background-color:#ffffee; width:700px;"| Requirement | ||
|- | |- | ||
| style="padding:5px; width:350px;" |[https://www.law.cornell.edu/cfr/text/42/493.1241 42 CFR Part 493.1241]<br />[https://www.aphl.org/aboutAPHL/publications/Documents/GH-2019May-LIS-Guidebook-web.pdf APHL 2019 LIS Project Management Guidebook]<br />[https://www.astm.org/e1578-18.html ASTM E1578-18 C-1-1] | | style="padding:5px; width:350px;" | | ||
[https://www.law.cornell.edu/cfr/text/21/part-1 21 CFR Part 1.1149]<br /> | |||
[https://www.law.cornell.edu/cfr/text/42/493.1241 42 CFR Part 493.1241]<br /> | |||
[https://www.aphl.org/aboutAPHL/publications/Documents/GH-2019May-LIS-Guidebook-web.pdf APHL 2019 LIS Project Management Guidebook]<br /> | |||
[https://www.astm.org/e1578-18.html ASTM E1578-18 C-1-1] | |||
| style="background-color:white;" |'''1.1''' The system should allow for sample registration prior to (e.g., preregistration) or after (e.g., registration) physical sample collection. | | style="background-color:white;" |'''1.1''' The system should allow for sample registration prior to (e.g., preregistration) or after (e.g., registration) physical sample collection. | ||
|- | |- | ||
| style="padding:5px; width:350px;" | | | style="padding:5px; width:350px;" | | ||
[https://www.law.cornell.edu/cfr/text/21/58.105 21 CFR Part 58.105 (c)]<br /> | [https://www.law.cornell.edu/cfr/text/21/58.105 21 CFR Part 58.105 (c)]<br /> | ||
[https://www.law.cornell.edu/cfr/text/21/211.84 21 CFR Part 211.84]<br /> | [https://www.law.cornell.edu/cfr/text/21/211.84 21 CFR Part 211.84]<br /> | ||
Line 97: | Line 100: | ||
[https://eur-lex.europa.eu/eli/dir/2003/94/oj E.U. Commission Directive 2003/94/EC Article 11.4]<br /> | [https://eur-lex.europa.eu/eli/dir/2003/94/oj E.U. Commission Directive 2003/94/EC Article 11.4]<br /> | ||
[https://www.iso.org/standard/56115.html ISO 15189:2012 5.7.2]<br /> | [https://www.iso.org/standard/56115.html ISO 15189:2012 5.7.2]<br /> | ||
[https://www.iso.org/standard/66912.html ISO/IEC 17025:2017 7.3.3]<br /> | |||
[https://www.wadsworth.org/regulatory/clep/clinical-labs/laboratory-standards NYSDOH CLEP Clinical Laboratory Standards of Practice, General Systems Standards]<br /> | [https://www.wadsworth.org/regulatory/clep/clinical-labs/laboratory-standards NYSDOH CLEP Clinical Laboratory Standards of Practice, General Systems Standards]<br /> | ||
[https://www.oecd.org/chemicalsafety/testing/oecdseriesonprinciplesofgoodlaboratorypracticeglpandcompliancemonitoring.htm OECD GLP Principles 6.1]<br /> | [https://www.oecd.org/chemicalsafety/testing/oecdseriesonprinciplesofgoodlaboratorypracticeglpandcompliancemonitoring.htm OECD GLP Principles 6.1]<br /> | ||
Line 104: | Line 108: | ||
[https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Sampling Procedures for PDP 5.1]<br /> | [https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Sampling Procedures for PDP 5.1]<br /> | ||
[https://extranet.who.int/prequal/content/who-technical-report-series WHO Technical Report Series, #986, Annex 2, 17.11 and 17.21] | [https://extranet.who.int/prequal/content/who-technical-report-series WHO Technical Report Series, #986, Annex 2, 17.11 and 17.21] | ||
| style="background-color:white;" |'''1.9''' The system shall be able to define the collection details for registered samples or specimens, including container size and type, number of containers, collection date and time, temperature, name of the collector, lot number, storage location, preservation method, collection methods used (standard and nonstandard), safety concerns, and retention period. | | style="background-color:white;" |'''1.9''' The system shall be able to define the collection and sampling details for registered samples or specimens, including container size and type, number of containers, collection date and time, temperature, name of the collector, lot number, storage location, preservation method, collection methods used (standard and nonstandard), sampling methods used, safety concerns, and retention period. | ||
|- | |- | ||
| style="padding:5px; width:350px;" | | | style="padding:5px; width:350px;" | | ||
Line 183: | Line 187: | ||
[https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.4.13]<br /> | [https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.4.13]<br /> | ||
[https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.11.8]<br /> | [https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.11.8]<br /> | ||
[https://www.iso.org/standard/66912.html ISO/IEC 17025:2017 7.4.3]<br /> | |||
[https://www.wadsworth.org/regulatory/clep/clinical-labs/laboratory-standards NYSDOH CLEP Clinical Laboratory Standards of Practice, General Systems Standards]<br /> | [https://www.wadsworth.org/regulatory/clep/clinical-labs/laboratory-standards NYSDOH CLEP Clinical Laboratory Standards of Practice, General Systems Standards]<br /> | ||
[https://www.pfp-ifss.org/ifss-resources/human-and-animal-food-testing-laboratories-best-practices-manual-december-2018/ PFP Human and Animal Food Testing Laboratories Best Practices Manual]<br /> | [https://www.pfp-ifss.org/ifss-resources/human-and-animal-food-testing-laboratories-best-practices-manual-december-2018/ PFP Human and Animal Food Testing Laboratories Best Practices Manual]<br /> | ||
Line 224: | Line 229: | ||
[https://mygfsi.com/news-and-resources/?_keyword=GFSI%20Benchmarking%20Requirements&_type=publications GFSI Benchmarking Rqmts., v2020.1, Part 3, D - FSM 14.1.2]<br /> | [https://mygfsi.com/news-and-resources/?_keyword=GFSI%20Benchmarking%20Requirements&_type=publications GFSI Benchmarking Rqmts., v2020.1, Part 3, D - FSM 14.1.2]<br /> | ||
[https://mygfsi.com/news-and-resources/?_keyword=GFSI%20Benchmarking%20Requirements&_type=publications GFSI Benchmarking Rqmts., v2020.1, Part 3, I - FSM 14.1.3]<br /> | [https://mygfsi.com/news-and-resources/?_keyword=GFSI%20Benchmarking%20Requirements&_type=publications GFSI Benchmarking Rqmts., v2020.1, Part 3, I - FSM 14.1.3]<br /> | ||
[https://csrc.nist.gov/publications/detail/sp/800-53/rev-5/final NIST 800-53, Rev. 5, AU-10(3)]<br /> | |||
[https://www.pfp-ifss.org/ifss-resources/human-and-animal-food-testing-laboratories-best-practices-manual-december-2018/ PFP Human and Animal Food Testing Laboratories Best Practices Manual]<br /> | [https://www.pfp-ifss.org/ifss-resources/human-and-animal-food-testing-laboratories-best-practices-manual-december-2018/ PFP Human and Animal Food Testing Laboratories Best Practices Manual]<br /> | ||
[https://www.sqfi.com/wp-content/uploads/2020/11/20227FMIN_FoodManufacturing_v3-2-FINAL-w-links.pdf SQF FSC 9, Food Manufacturing, Part B, 2.6.2]<br /> | [https://www.sqfi.com/wp-content/uploads/2020/11/20227FMIN_FoodManufacturing_v3-2-FINAL-w-links.pdf SQF FSC 9, Food Manufacturing, Part B, 2.6.2]<br /> |