[https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Sample Processing and Analysis Procedures for PDP 5.9–10]<br /> | [https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Sample Processing and Analysis Procedures for PDP 5.9–10]<br /> | ||
[https://www.wada-ama.org/en/resources/world-anti-doping-program/international-standard-laboratories-isl WADA International Standard for Laboratories (ISL) 5.3.12.1] | [https://www.wada-ama.org/en/resources/world-anti-doping-program/international-standard-laboratories-isl WADA International Standard for Laboratories (ISL) 5.3.12.1] | ||
| style="background-color:white;" |'''5.1''' The system shall accurately record details of a sample | | style="background-color:white;" |'''5.1''' The system shall accurately record all details of a sample's final disposition, including, when applicable, storage container type and ID, disposal method, disposal location, person responsible for disposition, etc. | ||
|- | |- | ||
| style="padding:5px; width:500px;" | | | style="padding:5px; width:500px;" | | ||
Line 25: | Line 25: | ||
|- | |- | ||
| style="padding:5px; width:500px;" |[https://www.law.cornell.edu/cfr/text/21/211.160 21 CFR Part 211.160 (b)]<br />[https://www.astm.org/e1578-18.html ASTM E1578-18 C-5-3]<br />[https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=30006MXP.PDF EPA 815-R-05-004 Chap. IV, Sec. 6.1] | | style="padding:5px; width:500px;" |[https://www.law.cornell.edu/cfr/text/21/211.160 21 CFR Part 211.160 (b)]<br />[https://www.astm.org/e1578-18.html ASTM E1578-18 C-5-3]<br />[https://nepis.epa.gov/Exe/ZyPDF.cgi?Dockey=30006MXP.PDF EPA 815-R-05-004 Chap. IV, Sec. 6.1] | ||
| style="background-color:white;" |'''5.3''' The system should provide appropriate functions for specific sample statuses like "approved" and " | | style="background-color:white;" |'''5.3''' The system should provide appropriate functions for specific sample statuses like "approved," "rejected," and "cancelled," including the ability to handle re-test, re-sampling, re-calculation, out-of-specification response and notification, and disposition functions. | ||
|- | |- | ||
|} | |} | ||
|} | |} |