|
|
(177 intermediate revisions by the same user not shown) |
Line 1: |
Line 1: |
| <div class="nonumtoc">__TOC__</div>
| | ==This is demo code demoing math== |
| {{ombox
| |
| | type = notice
| |
| | style = width: 960px;
| |
| | text = This is sublevel2 of my sandbox, where I play with features and test MediaWiki code. If you wish to leave a comment for me, please see [[User_talk:Shawndouglas|my discussion page]] instead.<p></p>
| |
| }}
| |
|
| |
|
| ==Sandbox begins below==
| | As a typical example, from a [[calibration plot]] following a [[linear equation]] taken here as the simplest possible model: |
|
| |
|
| ==AB Sciex Pte. Ltd.== | | : <math>f(x) = ax + b </math> |
| '''Main landing page for cannabis testing''': https://sciex.com/applications/food-and-beverage-testing/cannabis-testing
| |
|
| |
|
| Commonly known as Sciex, AB Sciex Pte. Ltd. develops "solutions in mass spectrometry paired with capillary electrophoresis and liquid chromatography."<ref name="SciexAbout">{{cite web |url=https://sciex.com/about-us |title=About Us |publisher=AB Sciex Pte. Ltd |accessdate=20 November 2018}}</ref> The company markets some of its solutions for cannabis lab testing, including<ref name="SciexCanna">{{cite web |url=https://sciex.com/applications/food-and-beverage-testing/cannabis-testing |title=Grow Your Cannabis Lab's Potential and Bottom Line with LC-MS/MS Analysis |publisher=AB Sciex Pte. Ltd |accessdate=20 November 2018}}</ref>:
| | where, <math>f(x)</math> corresponds to the signal measured (e.g. voltage, luminescence, energy, etc.) |
| | |
| * pesticide testing
| |
| * potency testing
| |
| * mycotoxin testing
| |
| * terpenes testing
| |
| | |
| ===Instruments===
| |
| 1. Sciex offers four different Triple Quad systems for LC-MS/MS: the 6500+, 5500, 4500, and 3500.
| |
| | |
| ====6500+====
| |
| The [https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-6500plus-system 6500+] has the following key features, per the website<ref name="Sciex6500+">{{cite web |url=https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-6500plus-system |title=SCIEX Triple Quad 6500+ LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:
| |
| | |
| ''Mass Range'': 5-2000 Da
| |
| | |
| ''Features'': IonDrive QJet, HED Detector
| |
| | |
| ''Detector Type'': IonDrive High Energy Detector+
| |
| | |
| ''Scan Types'': Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM, EMS, EPI, ER, MS3, MRM3
| |
| | |
| ''Ionization Sources/Options'': IonDrive Turbo V; OptiFlow™ Turbo V; TurboIonSpray®; Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®+
| |
| | |
| ====5500====
| |
| The [https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-5500-system 5500] has the following key features, per the website<ref name="Sciex5500">{{cite web |url=https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-5500-system |title=SCIEX Triple Quad 5500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:
| |
| | |
| ''Mass Range'': 5-1250 Da
| |
| | |
| ''Features'': Turbo V, Pulse Counting Detector
| |
| | |
| ''Detector Type'': AcQuRate Pulse Counting Detector
| |
| | |
| ''Scan Types'': Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
| |
| | |
| ''Ionization Sources'': Turbo V, OptiFlow Turbo V, TurboIonSpray® Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®
| |
| | |
| ====4500====
| |
| The [https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-4500-system 4500] has the following key features, per the website<ref name="Sciex4500">{{cite web |url=https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-4500-system |title=SCIEX Triple Quad 5500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:
| |
| | |
| ''Mass Range'': 5-2000 Da
| |
| | |
| ''Detector Type'': AcQuRate Pulse Counting Detector
| |
| | |
| ''Scan Types'': Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
| |
| | |
| ''Ionization Sources'': Turbo V; TurboIonSpray; Atmospheric-pressure chemical ionization (APCI); DuoSpray®, and NanoSpray® III
| |
| | |
| ====3500====
| |
| The [https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-3500-system 3500] has the following key features, per the website<ref name="Sciex3500">{{cite web |url=https://sciex.com/products/mass-spectrometers/triple-quad-systems/triple-quad-3500-system |title=SCIEX Triple Quad 5500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:
| |
| | |
| ''Mass Range'': 5 – 2000 Da
| |
| | |
| ''Features'': Turbo V, Pulse Counting Detector
| |
| | |
| ''Detector Type'': AcQuRate Pulse Counting Detector
| |
| | |
| ''Scan Types'': Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM
| |
| | |
| ''Ionization Sources'': TurboV ion source with TurboIonSpray™ and APCI probes
| |
| | |
| 2. Sciex also offers three different Triple Quad Linear Ion Traps (QTRAP) systems for LC-MS/MS: the 6500+, 5500, and 4500. The company states that these are similar to the Triple Quad systems "but with enhanced scan functions to enable simultaneous quantitation and confirmation."<ref name="SciexQTRAP">{{cite web |url=https://sciex.com/products/mass-spectrometers/qtrap-systems |title=QTRAP LC-MS/MS Systems |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>
| |
| | |
| ====QTRAP 6500+====
| |
| The [https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-6500plus-system QTRAP 6500+] has the following key features, per the website<ref name="SciexQTRAP6500+">{{cite web |url=https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-6500plus-system |title=QTRAP 6500+ LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:
| |
| | |
| ''Mass Range'': Dual switchable mass range: up to 1250 Da or up to 2000 Da
| |
| | |
| ''Features'': IonDrive QJet, HED Detector
| |
| | |
| ''Detector Type'': IonDrive High Energy Detector+
| |
| | |
| ''Scan Types'': Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM, EMS, EPI, ER, MS3, MRM3, TripleTrap™ Scanning
| |
| | |
| ''Ionization Sources/Options'': IonDrive Turbo V; OptiFlow™ Turbo V; TurboIonSpray®; Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®+
| |
| | |
| ====QTRAP 5500====
| |
| The [https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-5500-system QTRAP 5500] has the following key features, per the website<ref name="SciexQTRAP5500">{{cite web |url=https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-5500-system |title=QTRAP 5500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:
| |
| | |
| ''Mass Range'': Dual mass range Up to 1250 Da
| |
| | |
| ''Features'': Turbo V, Turbo V OptiFlow™, Pulse Counting Detector
| |
| | |
| ''Detector Type'': AcQuRate Pulse Counting Detector
| |
| | |
| ''Scan Types'': Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM, EMS, EPI, ER, MS3, MRM3, TripleTrap™ Scanning
| |
| | |
| ''Ionization Sources'': Turbo V OptiFlow™, TurboIonSpray Atmospheric-pressure chemical ionization (APCI); DuoSpray™, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource, SelexION®
| |
| | |
| ====QTRAP 4500====
| |
| The [https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-4500-system QTRAP 4500] has the following key features, per the website<ref name="SciexQTRAP4500">{{cite web |url=https://sciex.com/products/mass-spectrometers/qtrap-systems/qtrap-4500-system |title=QTRAP 4500 LC-MS/MS System |publisher=AB Sciex Pte. Ltd |accessdate=21 November 2018}}</ref>:
| |
| | |
| ''Mass Range'': Up to 2000 Da
| |
| | |
| ''Features'': Turbo V, Pulse Counting Detector
| |
| | |
| ''Detector Type'': AcQuRate Pulse Counting Detector
| |
| | |
| ''Scan Types'': Q1 MS, Q3 MS, Product Ion, Precursor Ion, Neutral Loss or Gain, MRM, EMS, EPI, ER, MS3, MRM3, TripleTrap Scanning
| |
| | |
| ''Ionization Sources'': Turbo V; TurboIonSpray; Atmospheric-pressure chemical ionization (APCI); DuoSpray®, and NanoSpray® III, Phytronix LDTD, Advion LESA Clarity, Digital PicoView, NanoSource
| |
| | |
| ==References==
| |
| {{Reflist|colwidth=30em}}
| |