Difference between revisions of "Journal:Timely delivery of laboratory efficiency information, Part II: Assessing the impact of a turnaround time dashboard at a high-volume laboratory"
Shawndouglas (talk | contribs) (Saving and adding more.) |
Shawndouglas (talk | contribs) (Finished adding rest of content.) |
||
(4 intermediate revisions by the same user not shown) | |||
Line 18: | Line 18: | ||
|website = [https://ajlmonline.org/index.php/ajlm/article/view/948/1475 https://ajlmonline.org/index.php/ajlm/article/view/948/1475] | |website = [https://ajlmonline.org/index.php/ajlm/article/view/948/1475 https://ajlmonline.org/index.php/ajlm/article/view/948/1475] | ||
|download = [https://ajlmonline.org/index.php/ajlm/article/download/948/1473 https://ajlmonline.org/index.php/ajlm/article/download/948/1473] (PDF) | |download = [https://ajlmonline.org/index.php/ajlm/article/download/948/1473 https://ajlmonline.org/index.php/ajlm/article/download/948/1473] (PDF) | ||
}} | }} | ||
Line 40: | Line 34: | ||
==Introduction== | ==Introduction== | ||
[[wikipedia:Turnaround time|Turnaround time]] (TAT) is an important performance indicator of a [[laboratory]]'s efficiency in delivering patient results.<ref name="HawkinsLab07">{{cite journal |title=Laboratory turnaround time |journal=The Clinical Biochemist |author=Hawkins, R.C. |volume=28 |issue=4 |pages=179–94 |year=2007 |pmid=18392122 |pmc=PMC2282400}}</ref> In the South African National Health Laboratory Services, ''ad hoc'' mean TAT reports were previously produced for laboratory managers. These TAT reports assessed performance based on the National Health Laboratory Service global annual performance plan (APP) TAT cutoffs specific to individual tests.<ref name="NHLSAnn1819">{{cite book |url=https://nationalgovernment.co.za/entity_annual/1714/2018-national-health-laboratory-service-(nhls)-annual-report.pdf |format=PDF |title=National Health Laboratory Service Annual Report 2017/18 |author=National Health Laboratory Service |publisher=National Health Laboratory Service |year=2018 |isbn=9780621457018}}</ref> Reports were provided intermittently in a static form that assessed central tendency only (i.e., the tail size was not reported) and did not allow for drilling down to access additional, more detailed [[information]] to direct meaningful corrective action (i.e., laboratory or sample-level TAT breakdown). To improve on these TAT reporting systems, Coetzee ''et al.'' used three additional measures to assess TAT efficiency: (1) median TAT, (2) 75th percentile TAT (tail size), and (3) percentage of within cutoff TAT.<ref name="CoetzeeTheImport18">{{cite journal |title=The importance of reporting individual weekly laboratory turn-around-time (TAT) to identify outliers and underperformance masked during global annual TAT review |journal=Proceedings of the African Society for Laboratory Medicine Conference 2018 |author=Coetzee, L.M.; Cassim, N.; Tepper, M.E.E. et al. |year=2018 |url=https://www.researchgate.net/publication/329610644}}</ref> These measures accurately assessed outliers as tail size and could be used by laboratories to address workflow issues and identify testing delays for intervention. "Tail size" refers to the volume of [[Sample (material)|samples]] in a positively skewed data distribution that has a long tail to the right. These samples often have a much higher TAT value than the central tendency (median) for this data distribution. Tail size can be measured as the percentage of samples that exceed a defined TAT cutoff in hours, or as a percentile. | [[wikipedia:Turnaround time|Turnaround time]] (TAT) is an important performance indicator of a [[laboratory]]'s efficiency in delivering patient results.<ref name="HawkinsLab07">{{cite journal |title=Laboratory turnaround time |journal=The Clinical Biochemist |author=Hawkins, R.C. |volume=28 |issue=4 |pages=179–94 |year=2007 |pmid=18392122 |pmc=PMC2282400}}</ref> In the South African National Health Laboratory Services, ''ad hoc'' mean TAT reports were previously produced for laboratory managers. These TAT reports assessed performance based on the National Health Laboratory Service global annual performance plan (APP) TAT cutoffs specific to individual tests.<ref name="NHLSAnn1819">{{cite book |url=https://nationalgovernment.co.za/entity_annual/1714/2018-national-health-laboratory-service-(nhls)-annual-report.pdf |format=PDF |title=National Health Laboratory Service Annual Report 2017/18 |author=National Health Laboratory Service |publisher=National Health Laboratory Service |year=2018 |isbn=9780621457018}}</ref> Reports were provided intermittently in a static form that assessed central tendency only (i.e., the tail size was not reported) and did not allow for drilling down to access additional, more detailed [[information]] to direct meaningful corrective action (i.e., laboratory or sample-level TAT breakdown). To improve on these TAT reporting systems, Coetzee ''et al.'' used three additional measures to assess TAT efficiency: (1) median TAT, (2) 75th percentile TAT (tail size), and (3) percentage of within cutoff TAT.<ref name="CoetzeeTheImport18">{{cite journal |title=The importance of reporting individual weekly laboratory turn-around-time (TAT) to identify outliers and underperformance masked during global annual TAT review |journal=Proceedings of the African Society for Laboratory Medicine Conference 2018 |author=Coetzee, L.M.; Cassim, N.; Tepper, M.E.E. et al. |year=2018 |url=https://www.researchgate.net/publication/329610644 |quote=Poster ID: PS-2.3b-070}}</ref> These measures accurately assessed outliers as tail size and could be used by laboratories to address workflow issues and identify testing delays for intervention. "Tail size" refers to the volume of [[Sample (material)|samples]] in a positively skewed data distribution that has a long tail to the right. These samples often have a much higher TAT value than the central tendency (median) for this data distribution. Tail size can be measured as the percentage of samples that exceed a defined TAT cutoff in hours, or as a percentile. | ||
Initially, the three measures described above were reported in Microsoft Excel (Redmond, Washington, United States) worksheet format from August 2016 to June 2017.<ref name="Microsoft">{{cite web |url=https://www.microsoft.com/en-za/microsoft-365/products-apps-services |title=Apps and services |publisher=Microsoft |accessdate=12 March 2019}}</ref> Thereafter, from July 2017, an interactive dashboard was developed that reported TAT data for a basket of tests using the Microstrategy Desktop (Tysons, Virginia, United States) analytics tool.<ref name="MicroStratDesk">{{cite web |url=https://www.microstrategy.com/en/get-started/desktop |title=Download MicroStrategy Desktop |publisher=MicroStrategy |accessdate=03 December 2018}}</ref> The previous static reports and the more recent interactive dashboard reports have seen distribution to area (province), business (district), and laboratory managers. Data can now be reviewed in the interactive dashboard reports across the provincial, district or laboratory levels through drill-down functionality, which makes it possible to slice through a data hierarchy to reveal additional details<ref name="MicrosoftDrill">{{cite web |url=https://docs.microsoft.com/en-us/power-bi/consumer/end-user-drill |title=Drill mode in a visual in Power BI |author=Microsoft |accessdate=12 December 2018}}</ref> contained within the aggregated data. In this way, TAT data presented can be visualized at the national, provincial, and laboratory level on the same dashboard page. The approach allows various levels of manager to drill down from a "bird’s-eye" view of TAT performance nationally, down to the provincial or individual laboratory level. | |||
Within the dashboard, TAT can be viewed for a basket of tests, including: | |||
* routine [[hematology]] such as full blood count with platelet and differential testing, international normalized ratio, activated prothrombin testing, and D-dimers; | |||
* [[clinical pathology]] testing such as urea and electrolytes, liver function testing, glucose, and cholesterol; | |||
* microbiology testing such as HIV (HIV viral load, HIV DNA polymerase chain reaction), tuberculosis (Xpert MTB/RIF), and syphilis (rapid plasma reagin and ''Treponema pallidum'' antibodies); and | |||
* other disease testing methods such as cluster of differentiation 4 (CD4) testing. | |||
Proxy marker analytes are used to assess performance of the respective matched assay panel; for example, creatinine is used as the proxy test to review urea and electrolytes performance. Each test has its own predetermined TAT determined at the local level according to the level of care, with absolute national APP cutoffs noted. | |||
Global TAT outcomes for each test are reported according to specifically stipulated, organization-determined TAT APP at the national level and are described elsewhere.<ref name="NHLSAnn1819" /><ref name="CassimFac1_20">{{cite journal |title=Timely delivery of laboratory efficiency information, Part I: Developing an interactive turnaround time dashboard at a high-volume laboratory |journal=African Journal of Laboratory Medicine |author=Cassim, N.; Tepper, M.E.; Coetzee, L.M.; Glencross, D.K. |volume=9 |issue=2 |at=a947 |year=2020 |doi=10.4102/ajlm.v9i2.947 |pmid=32391244 |pmc=PMC7203318}}</ref> National APP cutoffs are set bearing in mind the multi-tiered service that accommodates reporting from primary health care referral to large tertiary centers that may offer emergency services, and do not necessarily reflect the respective individual, laboratory-stipulated TAT, which may be self-determined by laboratories based on their local clinical needs. | |||
Armed with the knowledge of TAT and which tests are identified as poor performers in the interactive dashboard, laboratory managers can identify and address areas of concern through review of the contributing causes.<ref name="KhanRoot14">{{cite journal |title=Root Cause Analysis (RCA) of Prolonged Laboratory Turnaround Time in a Tertiary Care Set Up |journal=Journal of Clinical and Diagnostic Research |author=Khan, K. |volume=8 |issue=4 |pages=FC05–FC08 |doi=10.7860/JCDR/2014/7269.4255 |pmid=24959450 |pmc=PMC4064846}}</ref> This is achieved through root cause analysis, a method of problem solving used to identify the root causes (faults or problems) and determine the most probable underlying causes of error.<ref name="KhanRoot14" /> The ultimate aim of root cause analysis in TAT monitoring is to formulate corrective actions that either mitigate or eliminate the identified causes in order to return TAT efficiency and performance to acceptable levels. | |||
The aim of this study was to report on the impact of an interactive dashboard that provides weekly information about TAT and enables laboratory and senior managers to monitor TAT, as well as identify problematic areas for corrective action. The hypothesis was that an interactive TAT dashboard delivering week-by-week information about laboratory TAT provides the impetus for continuous service review and implementation of appropriate corrective action, where required, to ensure the timeliness of laboratory reporting. Data are presented from a single busy, routinely automated clinical pathology laboratory at a large regional [[hospital]] to reveal how the described TAT dashboard served to continually highlight ongoing TAT delays for urea and electrolyte (creatinine) result reporting and, ultimately, facilitated sustained corrective action. | |||
==Methods== | |||
===Ethical considerations=== | |||
Ethics clearance was obtained from the University of the Witwatersrand (study approval number: M1706108). No patient identifiers were extracted with data. | |||
===Study design and samples used=== | |||
A retrospective descriptive study design was used to analyze laboratory data and highlight the impact of interventions by observing trends. Qualitative focus group sessions were used to unpack the root causes of poor performance. Convenience sampling was used. For the purpose of this study, the TAT performance for creatinine testing, which had poor TAT at the start of the study, was used to demonstrate how dashboard monitoring of TAT could highlight and impact the TAT. Creatinine testing outcomes were reported with an APP cutoff of 90% within five hours.<ref name="NHLSAnn1819" /> Weekly TAT data—from the week August 1, 2016 to August 7, 2016 (week one), through to the week November 26, 2018 to December 2, 2018 (week 122)—was reviewed. | |||
===Data extraction and turnaround time definition=== | |||
The data extract contained the following variables: | |||
* report week ending date, e.g., October 23, 2016 (Monday to Sunday) | |||
* laboratory name | |||
* test method name | |||
* TAT cutoff | |||
* test volumes | |||
* percentage of within cutoff TAT | |||
* median TAT | |||
* 75th percentile TAT | |||
* inter-laboratory referral 75th percentile TAT | |||
* testing 75th percentile TAT | |||
* review 75th percentile TAT | |||
All TAT 75th percentile values were reported in hours. Each week was numbered, that is, 1–122. TAT data refer to total TAT (i.e., time of first registration to time of result release after review) if not otherwise specified for TAT components. All data were prepared and analyzed using Microsoft Excel (Redmond, Washington, United States).<ref name="Microsoft" /> The testing TAT time interval was calculated from time of registration in the testing laboratory to time of result generation on the analyzer interface. Review TAT (labeled <code>TST-TO-RVW</code> [test-to-review]) is the time taken by a senior technologist to review the patients’ results on the [[laboratory information system]] (LIS), making sure all quality checks were adequately performed before releasing (authorizing) the patients report. The recorded time interval, that is, the review TAT, was calculated afterwards for each individual sample outcome, from the time of result generation to the time of authorization or review. | |||
===Percentage within cutoff turnaround time analysis=== | |||
The percentage of within cutoff TAT was calculated as the total number of samples meeting the organization’s TAT cutoff criteria of five hours for urea and electrolytes testing divided by the total number of tests performed, expressed as a percentage, per week. The results were reported as a line chart (indicating the week number and APP cutoff of 90%). Data were segmented into three phases: (1) baseline: week 1 to 44 (week ending June 4, 2017); (2) dashboard intervention: week 45 to 63 (week ending October 15, 2017); and (3) post-intervention from week 64 to 122 (week ending December 2, 2018). The dashboard intervention period indicates the switch from using an Excel worksheet to the interactive dashboard. | |||
===75th percentile turnaround time analysis=== | |||
The 75th percentile was calculated for total TAT per week, as well as for TAT components, that is, testing and review. As tests were based out of a local hospital and not referred from surrounding laboratories, the pre-analytical TAT component was not applicable. When samples are referred, the pre-analytical TAT measures the interval (time taken to transport the sample between laboratories) from registration at the source (the laboratory where the sample was received) to the testing laboratory. Results from this analysis were plotted as 75th percentile, per testing week, for both total and component TAT. | |||
===Root cause analysis=== | |||
A root cause or Ishikawa analysis diagram was used to identify potential factors causing poor TAT performance.<ref name="IshikawaGuide76">{{cite book |title=Guide to Quality Control |author=Ishikawa, K. |edition=2nd Revised |publisher=Asian Productivity Organization |year=1976 |isbn=9283310365 |url=https://archive.org/details/guidetoqualityco00ishi/page/n7/mode/2up}}</ref> Causes were grouped into the following headings: (1) equipment and supplies; (2) environmental; (3) rules, policies, or procedures; and (4) staff or personnel. Focus group meetings were arranged with the laboratory manager and section supervisors to identify causes and to populate the cause-and-effect diagram. A voice recorder was used to create the cause-and-effect diagram using Microsoft Visio (Redmond, Washington, United States).<ref name="Microsoft" /> | |||
==Results== | |||
This laboratory performed 326,081 tests for the 2016/2017 financial period, 341,760 tests for the 2017/2018 financial period, and 399,538 tests for the 2018/2019 financial period. Assuming 24/7 operations, this equates to between 894 and 1,095 tests per day (N. Booplal, 2019, personal communication). Prior to the implementation of the interactive dashboard, weekly TAT data were extracted from the corporate [[data warehouse]] that houses LIS data within the National Health Laboratory Service. Weekly Microsoft Excel worksheets were prepared manually and distributed via email prior to the implementation of the interactive dashboard at week 45. | |||
===Percentage of within cutoff turnaround time analysis=== | |||
For the baseline phase, the percentage of TAT within the cutoff fluctuated (range: 10% to 79%) (Figure 1). During the intervention, the TAT range again fluctuated from 59% to 97%. For the post-intervention phase, the percentage of TAT with the cutoff ranged from 89% to 98%. The 90% cutoff was met for 42 consecutive weeks from week 81 to the end of the study period. | |||
[[File:Fig1 Cassim AfricanJLabMed2020 9-2-b.jpg|1100px]] | |||
{{clear}} | |||
{| | |||
| STYLE="vertical-align:top;"| | |||
{| border="0" cellpadding="5" cellspacing="0" width="1100px" | |||
|- | |||
| style="background-color:white; padding-left:10px; padding-right:10px;"| <blockquote>'''Fig. 1.''' The percentage of within cutoff turnaround times for creatinine testing at a high-volume laboratory across 122 weeks after implementation of a weekly dashboard, Gauteng, South Africa, 2017</blockquote> | |||
|- | |||
|} | |||
|} | |||
===75th percentile turnaround time analysis=== | |||
During the baseline phase, the total TAT 75th percentile ranged from four to 20 hours, changing to two to 10 hours for the intervention phase (Figure 2). For the post-intervention phase, the 75th percentile range was two to three hours. For testing TAT, the 75th percentile for the baseline phase ranged from two to 11 hours and changed during the intervention phase to one to six hours. In the post-intervention phase, the range was one to two hours. In the baseline phase, the 75th percentile review TAT ranged from one to 15 hours, compared to one to three hours for the intervention phase. The post-intervention phase reported a 75th percentile review TAT of one hour or less. | |||
[[File:Fig2 Cassim AfricanJLabMed2020 9-2-b.jpg|1100px]] | |||
{{clear}} | |||
{| | |||
| STYLE="vertical-align:top;"| | |||
{| border="0" cellpadding="5" cellspacing="0" width="1100px" | |||
|- | |||
| style="background-color:white; padding-left:10px; padding-right:10px;"| <blockquote>'''Fig. 2.''' 75th percentile total turnaround time for creatinine testing at a high-volume laboratory across 122 weeks after implementation of an interactive weekly dashboard, Gauteng, South Africa, 2017</blockquote> | |||
|- | |||
|} | |||
|} | |||
===Root cause analysis=== | |||
Four major clusters of contributing causes were identified in the root cause analysis, including equipment and supplies; environmental causes; rules, policies, and procedural causes; and staff and personnel factors (Figure 3). | |||
With respect to equipment and supplies, the following causes were shown to have negatively impacted TAT: (1) migration to the new platform (phased approach), (2) difficulties with procurement of laptops to facilitate after-hours off-site authorization, (3) power outages, (4) LIS bandwidth challenges, (5) LIS upgrades, and (6) reagent or stock procurement. | |||
Insufficient air conditioning and water leaks from the ceiling were highlighted as causative environmental factors. | |||
Problems related to rules, policies, and procedures included (1) middleware having to be configured, tested, and amended due to the changes brought about by a phased approach, and (2) a substantial workload being transferred from a nearby laboratory without provision of additional testing or staffing capacity. | |||
For staff and personnel considerations, the following were identified: (1) after-hours authorization delay (by pathologists); (2) industrial action leading to delays; (3) paediatric and low-volume samples requiring manual processing, causing bottlenecks in the workflow; (4) staff constraints (in terms of insufficient staff to manage the benches); (5) additional training of staff being required for new procedures and processes for the platform testing changes implemented; (6) first-line manual sample preparation being needed to enable sample testing prior to full automation; and (7) training for the new platforms provided occurring on-site, while at the same time staff were also required to attend training off-site, leaving benches poorly staffed during training periods. | |||
[[File:Fig3 Cassim AfricanJLabMed2020 9-2-b.jpg|1100px]] | |||
{{clear}} | |||
{| | |||
| STYLE="vertical-align:top;"| | |||
{| border="0" cellpadding="5" cellspacing="0" width="1100px" | |||
|- | |||
| style="background-color:white; padding-left:10px; padding-right:10px;"| <blockquote>'''Fig. 3.''' Root cause analysis diagram developed in conjunction with the laboratory manager at a high-volume laboratory, Gauteng, South Africa, 2017</blockquote> | |||
|- | |||
|} | |||
|} | |||
==Discussion== | |||
In this study, it was hypothesized that the application of appropriate corrective action, guided by an interactive TAT dashboard indicating the proportion of samples within stipulated TAT cutoffs and tail size (outliers), would result in improved performance.<ref name="HawkinsLab07" /><ref name="CoetzeeUsing18">{{cite journal |title=Using laboratory data to categorise CD4 laboratory turn-around-time performance across a national programme |journal=African Journal of Laboratory Medicine |author=Coetzee, L.-M.; Cassim, N.; Glencross, D.K. |volume=7 |issue=1 |at=665 |year=2018 |doi=10.4102/ajlm.v7i1.665 |pmid=30167387 |pmc=PMC6111574}}</ref> This was based on the assumption that delivering an interactive TAT dashboard indicating outlier performance on its own would not result in improvement. Good laboratory management and response with appropriate corrective action is the key catalyst to deliver a sustained quality of reporting and ensure the continual TAT improvement of performance over time.<ref name="EzzelleGuide08">{{cite journal |title=Guidelines on good clinical laboratory practice: bridging operations between research and clinical research laboratories |journal=Journal of Pharmaceutical and Biomedical Analysis |author=Ezzelle, J.; Rodriguez-Chavez, I.R.; Darden, J.M. et al. |volume=46 |issue=1 |pages=18–29 |year=2008 |doi=10.1016/j.jpba.2007.10.010 |pmid=18037599 |pmc=PMC2213906}}</ref> | |||
All laboratories typically adhere to a [[quality management system]] (QMS) that is used to assess laboratory quality from the pre-analytic phase through the testing and reviewing processes. A QMS is defined as a set of coordinated activities that direct and control a laboratory with regard to quality.<ref name="WHOLab11">{{cite book |title=Laboratory Quality Management System Handbook |author=World Health Organization |publisher=World Health Organization |year=2011 |isbn=9789241548274 |url=https://www.who.int/ihr/publications/lqms_en.pdf |format=PDF}}</ref> All aspects of the laboratory operation, including the organizational structure, processes, and procedures need to be addressed by the QMS to assure quality.<ref name="WHOLab11" /> Laboratory quality can be defined in terms of accuracy, reliability, and timeliness (i.e., TAT).<ref name="WHOLab11" /> One of the key practices for [[Continual improvement process|continual improvement]] is the management review meeting, allowing the laboratory an opportunity to review annual performance as set out in the QMS. The management review cycle involves planning, implementing, checking, and acting on a quarterly basis to address shortfalls identified to affect continual improvement.<ref name="WHOLab11" /> | |||
In this study, we reveal how the introduction of a TAT dashboard enabled senior management of the laboratory in question to assess TAT performance for a particular battery of tests that had not met the stipulated TAT cutoff (greater than 65% of results were outside of the stipulated TAT cutoff). Upon introduction of the dashboard, several areas of concern were immediately identified, including pre-analytical, analytical, and post-analytical factors. With respect to component TAT, assessing specifically the timeframes of "registration to testing" and "testing to release of the report," TAT delays were attributable to delays of review during weeks one to 41, with further delays caused by testing (instrument) interruptions during weeks four and 48. The root cause analysis revealed several contributing factors, categorized as equipment and supplies; environmental; rules, policies, and procedures; and personnel or staffing issues. Specifically, the introduction of an auto-review rule process played an important role in improving TAT cutoff. A similarly placed high-volume core laboratory in Canada also reported that the implementation of a series of [[Lean laboratory|lean approaches]] in their busy laboratory, including automation and auto-review rules, proved effective for more efficiently managing substantial volumes of samples while meeting TAT cutoffs.<ref name="LouMulti17">{{cite journal |title=Multiple pre- and post-analytical lean approaches to the improvement of the laboratory turnaround time in a large core laboratory |journal=Clinical Biochemistry |author=Lou, A.H.; Elnenaei, M.O.; Sadek, I. et al. |volume=50 |issue=15 |pages=864–69 |year=2017 |doi=10.1016/j.clinbiochem.2017.04.019 |pmid=28457964}}</ref> | |||
Several important lessons learned and documented by the study laboratory could serve as a template for outreach training to help other public sector laboratories achieve similar TAT performance improvements and establish the practices adopted at this site. Firstly, the importance of the need to collate and actively review real-time information about TAT—including components of TAT, in ensuring overall timely reporting in laboratories—was understood and confirmed. Secondly, the value of vertical audits was demonstrated. Vertical audits assisted in understanding what contributed to delayed TAT, and specific focus on outlier samples and vertical audits directed subsequent meaningful corrective action. In line with the requirement of ongoing improvement of service delivery, a weekly "results for action" statement was developed and found to be useful to deliver specific information at the sample or episode level. Such reports, while getting the attention of senior management, could be directed to relevant managers to highlight specific problematic areas and guide the focus of managers’ attention to the investigation of true TAT outliers or exceptions. Such investigation (with solutions) of specifically identified problem areas could yield practical and advantageous outcomes, not only solving the issues at hand, but more widely having a positive impact on overall service delivery improvement. | |||
The final lesson learned revolved around the importance of documenting and following through on corrective actions as part of the QMS. This ensures that corrective actions taken have consequences and are sustained. In the services review presented here, the week-by-week reminders of outlying TAT were a constant cue that solutions implemented had not been effective. Re-evaluation and re-assessment allowed for streamlined processes to be considered when initial corrective actions had failed. Also highlighted was the importance of conducting a root cause analysis using cause-and-effect diagrams, to tease out and understand all aspects of errors and any contributing factors that may lead to delays in TAT. It is also important to point out that although a corrective action may be resolved with a single intervention, more frequently, corrective action proves to be a multi-step process to identify possible solutions and alternatives. Once implemented, these corrective steps require consistent monitoring and evaluation for sustained impact. Here, the information provided by the dashboard offered objective evidence of identified issues that could be documented and presented to senior managers from month to month and at the annual management meeting; that, in due course, enabled corrective action planning and the facilitated, necessary mandates to affect better service. | |||
===Past approaches to improving turnaround times=== | |||
Over the years, there have been multiple approaches to monitoring TAT reporting with the aim of improving TAT and, in turn, patient care. Approaches include identifying outliers, implementing Lean Sigma Six, and performing process mapping.<ref name="HawkinsLab07" /><ref name="BarakauskasProcess16">{{cite journal |title=Process Optimization to Improve Immunosuppressant Drug Testing Turnaround Time |journal=American Journal of Clinical Pathology |author=Barakauskas, V.E.; Bradshaw, T.A.; Smith, L.D. et al. |volume=146 |issue=2 |pages=182–90 |year=2016 |doi=10.1093/ajcp/aqw087 |pmid=27453440}}</ref><ref name="HollandReduc05">{{cite journal |title=Reducing laboratory turnaround time outliers can reduce emergency department patient length of stay: An 11-hospital study |journal=American Journal of Clinical Pathology |author=Holland, L.L.; Smith, L.L.; Blick, K.E. |volume=124 |issue=5 |pages=672–4 |year=2005 |doi=10.1309/E9QP-VQ6G-2FBV-MJ3B |pmid=16203280}}</ref><ref name="GrabanLean08">{{cite journal |title=Lean Laboratories: Competing with Methods From Toyota |journal=Laboratory Medicine |author=Graban, M.; Padgett, S. |volume=39 |issue=11 |pages=645–48 |year=2008 |doi=10.1309/LMX0LEMR7R0USKUM}}</ref><ref name="StapletonImprov12">{{cite journal |title=Improved Laboratory Stat Test Turnaround Time Using Lean Six Sigma |journal=American Journal of Clinical Pathology |author=Stapleton, K.; Sammond, D. |volume=138 |issue=Suppl. 2 |page=A184 |year=2012 |doi=10.1093/ajcp/138.suppl2.36}}</ref> One of the earliest approaches described was the identification of TAT outliers.<ref name="HawkinsLab07" /> In 2005, Holland ''et al.'' reported that the average length of stay in the emergency department across 11 hospitals correlated significantly with the percentage of outliers.<ref name="HollandReduc05" /> In 2007, Hawkins defined outliers as the TAT of samples that exceeded the institution’s agreed TAT cutoffs.<ref name="HawkinsLab07" /> Outliers could also be defined as the tail size given the skewed TAT distribution. Therefore, the mean and confidence interval are not appropriate measures for assessing TAT performance. In 2018, Coetzee ''et al.'' used the 75th percentile and the percentage of samples within the cutoff TAT to identify outliers at the laboratory and test levels.<ref name="CoetzeeUsing18" /> The development of routine monitoring systems to identify laboratories with a long tail size enabled focused interventions to proactively resolve poor service delivery.<ref name="CoetzeeUsing18" /> | |||
Many laboratories have implemented Lean Six Sigma approaches to improve TAT performance.<ref name="LouMulti17" /> "Lean" is defined as a continual improvement process consisting of technical tools and management methods.<ref name="GrabanLean08" /> One of the aims of a lean approach is to find and eliminate waste.<ref name="GrabanLean08" /> For example, waste may be introduced by the layout of a laboratory or by poor process design.<ref name="GrabanLean08" /> Long distances between the receiving office and testing laboratory could also, for example, encourage staff to move samples in batches resulting in TAT delays.<ref name="GrabanLean08" /> In 2008, Graban and Padgett reported that the introduction of lean approaches for troponin testing resulted in substantial TAT improvements and averted a proposed point-of-care testing implementation.<ref name="GrabanLean08" /> A 2012 report by Stapleton and Sammond showed how a lean approach implemented over a three-year period in the laboratory resulted in TAT reductions for all emergency tests by implementing both workflow improvements and a dedicated emergency bench.<ref name="StapletonImprov12" /> | |||
Another approach to improve TAT was reported by Barakauskas ''et al.'' in 2016, involving the use of LIS time stamps, direct observations, and discussions with staff to construct various value stream and process maps for immunosuppressant drug level testing.<ref name="BarakauskasProcess16" /> The value stream map identified process bottlenecks that were addressed.<ref name="BarakauskasProcess16" /> The process map was reported in columns to represent the major groups of personnel and locations from the health care worker to the reference testing laboratory, with the sequence of events and steps involved illustrated in a vertical direction.<ref name="BarakauskasProcess16" /> Bottlenecks were also identified in the process map to plan improvement initiatives, e.g., the use of emergency bags.<ref name="BarakauskasProcess16" /> | |||
Ultimately, the aim of any of the approaches described above is to improve TAT performance and, thus, patient care. Although TAT is especially important for emergency tests that have very short TAT cutoffs, it is equally important to set cutoffs for other, less urgent tests to ensure that respective test results are received by attending physicians in a timely fashion to affect appropriate patient care, an important factor in assuring both the quality of care and the cost-effective use of hospital services.<ref name="WinkelmanHowFast97">{{cite journal |title=How fast is fast enough for clinical laboratory turnaround time? Measurement of the interval between result entry and inquiries for reports |journal=American Journal of Clinical Pathology |author=Winkelman, J.W.; Tanasijevic, M.J.; Wybenga, D.R. et al. |volume=108 |issue=4 |pages=400–5 |year=1997 |doi=10.1093/ajcp/108.4.400 |pmid=9322592}}</ref> Aside from patient care, TAT delays also have the potential to waste valuable health resources caused by duplicate test requests, thereby increasing public health expenditure.<ref name="WinkelmanHowFast97" /> In summary, the multiple approaches to improving TAT performance across all laboratory tests play an important role in improving the quality of patient care. | |||
===Application to African contexts=== | |||
Figure 4 describes an approach that would make it possible for laboratories in low- and middle-income countries to collate the data required to develop the TAT reporting described in our study. In the first instance, laboratories would require a basic LIS that could generate weekly data extracts as described in Figure 4, using open-source database software such as Microsoft SQL Server (Express, Redmond, California, United States).<ref name="MSSQLServer">{{cite web |url=https://www.microsoft.com/en-us/sql-server/sql-server-2019 |title=SQL Server 2019 |author=Microsoft |accessdate=10 April 2019}}</ref> Equally, [[MySQL]]<ref name="MySQL">{{cite web |url=https://www.mysql.com/products/community/ |title=MySQL Community Edition |author=Oracle Corporation |accessdate=03 February 2019}}</ref>, Firebird<ref name="Firebird">{{cite web |url=https://firebirdsql.org/en/firebird-rdbms/ |title=Firebird RDBMS |author=Firebird Project |accessdate=10 April 2019}}</ref>, or [[CUBRID]]<ref name="Cubrid">{{cite web |url=https://www.cubrid.org/ |title=CUBRID |author=CUBRID Foundation |accessdate=10 April 2019}}</ref> could be deployed to generate the aggregate data described. Training is freely accessible via the internet for these software packages. There are multiple free online courses by providers via platforms such as edX, where one can learn how to both develop and query a structured query language (SQL) database.<ref name="edXQuerying">{{cite web |url=https://www.edx.org/course/querying-data-with-transact-sql-2 |title=Querying Data with Transact-SQL |author=Microsoft |work=edX |accessdate=03 April 2019}}</ref><ref name="edXDevelopingArch">{{cite web |url=http://www.edx.org/course/developing-sql-databases |archiveurl=https://web.archive.org/web/20200502074237/http://www.edx.org/course/developing-sql-databases |title=Developing SQL Databases |author=Microsoft |work=edX |archivedate=20 May 2020 |accessdate=03 April 2019}}</ref> Any of these software packages could be implemented on a local desktop or in a server environment, depending on the data volume, with very basic query tools using SQL commands, making it possible to develop dashboard tools using the step-by-step building blocks approach described in Figure 4. | |||
[[File:Fig4 Cassim AfricanJLabMed2020 9-2-b.jpg|1100px]] | |||
{{clear}} | |||
{| | |||
| STYLE="vertical-align:top;"| | |||
{| border="0" cellpadding="5" cellspacing="0" width="1100px" | |||
|- | |||
| style="background-color:white; padding-left:10px; padding-right:10px;"| <blockquote>'''Fig. 4.''' Integration of laboratory information system specimen-level turnaround time data from multiple laboratories into a single, aggregated structured query language database for development of an interactive dashboard, Gauteng, South Africa, 2017</blockquote> | |||
|- | |||
|} | |||
|} | |||
Cross-country collaboration and sharing of resources could play an important role in securing already developed dashboard tools for other African countries. A multi-country approach could reduce overall costs and effort. For example, a single TAT dashboard could be developed for the Southern African Development Community to ensure accessibility and provide scalability. To secure the system and provide confidentiality, each country could have access to their own data using data access privileges. The benefit of this approach is that after the methods, systems, and dashboards are developed, it is easy to extend these developments to other countries with minimal additional cost. The only additional effort required at the country level would be to collate and share the data extracts with the umbrella organizers. | |||
==Conclusion== | |||
In summary, this study demonstrated that an interactive TAT dashboard that reports appropriate TAT parameters, applied in the context of a QMS and coupled with proactive and diligent management, can accurately identify outliers and lead to appropriate corrective action and sustained timely laboratory reporting. | |||
===Limitations=== | |||
Only LIS data were used for our study. Without a laboratory specimen tracking system, it is not possible to report end-to-end TAT. The implementation of an end-to-end tracking system from the time of venesection to delivery into a laboratory, additionally integrated into a TAT dashboard, could provide valuable supplementary date and time values to allow for an extended TAT efficiency review. | |||
===Lessons from the field=== | |||
Our experiences in the field allow us provide a few lessons learned: | |||
* A weekly interactive TAT dashboard enables reporting of appropriate TAT paramaters and respective outcomes by confirming ongoing quality and timely reporting, as well as identifying outlying TAT that may require appropriate corrective action. | |||
* TAT data can be collected at the laboratory, local network, or national level. A dashboard that includes aggregated and local level data, with a drill-down function, allows hierarchical review of the data, such that both higher-level managers and laboratory managers are able to view the same data, but at different levels appropriate for their respective level of responsibility. | |||
* Continuously collating and analyzing the data and presenting TAT information in a user-friendly, visual dashboard format allows for immediate attention to be focused on outlying sites and areas. | |||
* Visibility and transparency of TAT data and outcomes to all levels of management provide an incentive (with repeated peer or organization pressure, if consistently outside of TAT) to act on poor performance. | |||
* A quality management system requires active input, monitoring, and appropriate action where needed. The presentation of information does not necessarily confer good performance or the meeting of TAT cutoffs. A dashboard, such as that presented here, is merely a tool. Proactive, consistent, and diligent review of TAT data presented in a dashboard is required to facilitate meaningful improvement and corrective action. An auto-review rule implemented for a specific test or battery of tests on the LIS has the potential to reduce TAT by acting to reduce the workload for senior staff through automatic review of predominantly normal results. With the auto-review implemented, senior staff effectively use their time and reserve the resultant review only for samples that fail to meet the auto-review rule, e.g., as with delta check failures. | |||
==Acknowledgements== | |||
The authors thank area, business, and laboratory managers in Gauteng for their participation and input. | |||
===Author contributions=== | |||
D.K.G. supervised the study by providing leadership and oversight as the project leader. N.C., M.E.E.T. and L.M.C. designed the study, developed the methodology and conducted the research. M.E.E.T. extracted the data. N.C. conducted the data analysis. L.P. provided content for the cause and effect diagram and provided details on the interventions implemented. D.K.G. provided editorial comments and technical input. All authors reviewed the results and contributed to the manuscript development. | |||
===Disclaimer=== | |||
The authors declare that the views expressed in the submitted article are their own and not the official position of any institution or funder. | |||
===Competing interests=== | |||
The authors declare no conflict of interest. The authors further declare that they have no financial or personal relationships that may have inappropriately influenced them in writing this article. | |||
==References== | ==References== | ||
Line 48: | Line 214: | ||
==Notes== | ==Notes== | ||
This presentation is faithful to the original, with only a few minor changes to presentation. Grammar was cleaned up for smoother reading. In some cases important information was missing from the references, and that information was added. The original citation number two (2017-2018 NHLS Annual Report) was dead; an alternately hosted version was found and used for this version. | This presentation is faithful to the original, with only a few minor changes to presentation. Grammar was cleaned up for smoother reading. In some cases important information was missing from the references, and that information was added. The original citation number two (2017-2018 NHLS Annual Report) was dead; an alternately hosted version was found and used for this version. The original cites Wikipedia concerning the Ishikawa diagram; as using Wikipedia as a citation is generally frowned upon, a substitute citation for Ishikawa's original ''Guide to Quality Control'' was used for this version. The original article accidentally mixed up citations 19 and 20; this was corrected for this version. The citation URL for the SQL Databases edX course is dead; an archived version of the URL is used for this version. The original article used an image for lessons learned in the field; this version skips the image and replaces it with the image text. | ||
<!--Place all category tags here--> | <!--Place all category tags here--> |
Latest revision as of 20:21, 24 January 2021
Full article title | Timely delivery of laboratory efficiency information, Part II: Assessing the impact of a turnaround time dashboard at a high-volume laboratory |
---|---|
Journal | African Journal of Laboratory Medicine |
Author(s) | Cassim, Naseem; Coetzee, Lindi M.; Tepper, Manfred E.; Perelson, Louella; Glencross, Deborah K. |
Author affiliation(s) | National Health Laboratory Service, University of the Witwatersrand |
Primary contact | Email: naseem dot cassim at wits dot ac dot za |
Year published | 2020 |
Volume and issue | 9(2) |
Article # | a948 |
DOI | 10.4102/ajlm.v9i2.948 |
ISSN | 2225-2010 |
Distribution license | Creative Commons Attribution 4.0 International License |
Website | https://ajlmonline.org/index.php/ajlm/article/view/948/1475 |
Download | https://ajlmonline.org/index.php/ajlm/article/download/948/1473 (PDF) |
Abstract
Background: In South Africa’s National Health Laboratory Service, ad hoc mean turnaround time (TAT) reporting is an important indicator of performance. However, historic static TAT reporting did not assess very long or very short times. An interactive TAT dashboard was developed using the following TAT measures: (1) median, (2) 75th percentile, and (3) percentage of within cutoff TAT to allow for improved differentiation of TAT performance.
Objectives: The objective of our study was to demonstrate increased efficiency achieved by using an interactive TAT dashboard.
Methods: A retrospective descriptive study design was used. Creatinine TAT outcomes were reported over 122 weeks from a high-volume laboratory in Gauteng, South Africa. The percentage of within cutoff and 75th percentile TAT were analyzed and reported using Microsoft Excel. A focus group session was used to populate a cause and effect diagram.
Results: The percentage of within cutoff TAT increased from 10% in week four to 90% and higher from week 81. The 75th percentile decreased from 10 hours in week four to under five hours from week 71. Component TAT analysis revealed that the 75th percentile testing was five hours or longer for weeks four, five and 48. The 75th percentile review TAT ranged from one hour to 15 hours. From week 41, the review TAT was under one hour.
Conclusion: Our study demonstrated that the use of an interactive TAT dashboard, coupled with good management, can dramatically improve TAT and efficiency in a high-volume laboratory.
Keywords: turnaround time, laboratory efficiency, pathology, laboratory medicine
Introduction
Turnaround time (TAT) is an important performance indicator of a laboratory's efficiency in delivering patient results.[1] In the South African National Health Laboratory Services, ad hoc mean TAT reports were previously produced for laboratory managers. These TAT reports assessed performance based on the National Health Laboratory Service global annual performance plan (APP) TAT cutoffs specific to individual tests.[2] Reports were provided intermittently in a static form that assessed central tendency only (i.e., the tail size was not reported) and did not allow for drilling down to access additional, more detailed information to direct meaningful corrective action (i.e., laboratory or sample-level TAT breakdown). To improve on these TAT reporting systems, Coetzee et al. used three additional measures to assess TAT efficiency: (1) median TAT, (2) 75th percentile TAT (tail size), and (3) percentage of within cutoff TAT.[3] These measures accurately assessed outliers as tail size and could be used by laboratories to address workflow issues and identify testing delays for intervention. "Tail size" refers to the volume of samples in a positively skewed data distribution that has a long tail to the right. These samples often have a much higher TAT value than the central tendency (median) for this data distribution. Tail size can be measured as the percentage of samples that exceed a defined TAT cutoff in hours, or as a percentile.
Initially, the three measures described above were reported in Microsoft Excel (Redmond, Washington, United States) worksheet format from August 2016 to June 2017.[4] Thereafter, from July 2017, an interactive dashboard was developed that reported TAT data for a basket of tests using the Microstrategy Desktop (Tysons, Virginia, United States) analytics tool.[5] The previous static reports and the more recent interactive dashboard reports have seen distribution to area (province), business (district), and laboratory managers. Data can now be reviewed in the interactive dashboard reports across the provincial, district or laboratory levels through drill-down functionality, which makes it possible to slice through a data hierarchy to reveal additional details[6] contained within the aggregated data. In this way, TAT data presented can be visualized at the national, provincial, and laboratory level on the same dashboard page. The approach allows various levels of manager to drill down from a "bird’s-eye" view of TAT performance nationally, down to the provincial or individual laboratory level.
Within the dashboard, TAT can be viewed for a basket of tests, including:
- routine hematology such as full blood count with platelet and differential testing, international normalized ratio, activated prothrombin testing, and D-dimers;
- clinical pathology testing such as urea and electrolytes, liver function testing, glucose, and cholesterol;
- microbiology testing such as HIV (HIV viral load, HIV DNA polymerase chain reaction), tuberculosis (Xpert MTB/RIF), and syphilis (rapid plasma reagin and Treponema pallidum antibodies); and
- other disease testing methods such as cluster of differentiation 4 (CD4) testing.
Proxy marker analytes are used to assess performance of the respective matched assay panel; for example, creatinine is used as the proxy test to review urea and electrolytes performance. Each test has its own predetermined TAT determined at the local level according to the level of care, with absolute national APP cutoffs noted.
Global TAT outcomes for each test are reported according to specifically stipulated, organization-determined TAT APP at the national level and are described elsewhere.[2][7] National APP cutoffs are set bearing in mind the multi-tiered service that accommodates reporting from primary health care referral to large tertiary centers that may offer emergency services, and do not necessarily reflect the respective individual, laboratory-stipulated TAT, which may be self-determined by laboratories based on their local clinical needs.
Armed with the knowledge of TAT and which tests are identified as poor performers in the interactive dashboard, laboratory managers can identify and address areas of concern through review of the contributing causes.[8] This is achieved through root cause analysis, a method of problem solving used to identify the root causes (faults or problems) and determine the most probable underlying causes of error.[8] The ultimate aim of root cause analysis in TAT monitoring is to formulate corrective actions that either mitigate or eliminate the identified causes in order to return TAT efficiency and performance to acceptable levels.
The aim of this study was to report on the impact of an interactive dashboard that provides weekly information about TAT and enables laboratory and senior managers to monitor TAT, as well as identify problematic areas for corrective action. The hypothesis was that an interactive TAT dashboard delivering week-by-week information about laboratory TAT provides the impetus for continuous service review and implementation of appropriate corrective action, where required, to ensure the timeliness of laboratory reporting. Data are presented from a single busy, routinely automated clinical pathology laboratory at a large regional hospital to reveal how the described TAT dashboard served to continually highlight ongoing TAT delays for urea and electrolyte (creatinine) result reporting and, ultimately, facilitated sustained corrective action.
Methods
Ethical considerations
Ethics clearance was obtained from the University of the Witwatersrand (study approval number: M1706108). No patient identifiers were extracted with data.
Study design and samples used
A retrospective descriptive study design was used to analyze laboratory data and highlight the impact of interventions by observing trends. Qualitative focus group sessions were used to unpack the root causes of poor performance. Convenience sampling was used. For the purpose of this study, the TAT performance for creatinine testing, which had poor TAT at the start of the study, was used to demonstrate how dashboard monitoring of TAT could highlight and impact the TAT. Creatinine testing outcomes were reported with an APP cutoff of 90% within five hours.[2] Weekly TAT data—from the week August 1, 2016 to August 7, 2016 (week one), through to the week November 26, 2018 to December 2, 2018 (week 122)—was reviewed.
Data extraction and turnaround time definition
The data extract contained the following variables:
- report week ending date, e.g., October 23, 2016 (Monday to Sunday)
- laboratory name
- test method name
- TAT cutoff
- test volumes
- percentage of within cutoff TAT
- median TAT
- 75th percentile TAT
- inter-laboratory referral 75th percentile TAT
- testing 75th percentile TAT
- review 75th percentile TAT
All TAT 75th percentile values were reported in hours. Each week was numbered, that is, 1–122. TAT data refer to total TAT (i.e., time of first registration to time of result release after review) if not otherwise specified for TAT components. All data were prepared and analyzed using Microsoft Excel (Redmond, Washington, United States).[4] The testing TAT time interval was calculated from time of registration in the testing laboratory to time of result generation on the analyzer interface. Review TAT (labeled TST-TO-RVW
[test-to-review]) is the time taken by a senior technologist to review the patients’ results on the laboratory information system (LIS), making sure all quality checks were adequately performed before releasing (authorizing) the patients report. The recorded time interval, that is, the review TAT, was calculated afterwards for each individual sample outcome, from the time of result generation to the time of authorization or review.
Percentage within cutoff turnaround time analysis
The percentage of within cutoff TAT was calculated as the total number of samples meeting the organization’s TAT cutoff criteria of five hours for urea and electrolytes testing divided by the total number of tests performed, expressed as a percentage, per week. The results were reported as a line chart (indicating the week number and APP cutoff of 90%). Data were segmented into three phases: (1) baseline: week 1 to 44 (week ending June 4, 2017); (2) dashboard intervention: week 45 to 63 (week ending October 15, 2017); and (3) post-intervention from week 64 to 122 (week ending December 2, 2018). The dashboard intervention period indicates the switch from using an Excel worksheet to the interactive dashboard.
75th percentile turnaround time analysis
The 75th percentile was calculated for total TAT per week, as well as for TAT components, that is, testing and review. As tests were based out of a local hospital and not referred from surrounding laboratories, the pre-analytical TAT component was not applicable. When samples are referred, the pre-analytical TAT measures the interval (time taken to transport the sample between laboratories) from registration at the source (the laboratory where the sample was received) to the testing laboratory. Results from this analysis were plotted as 75th percentile, per testing week, for both total and component TAT.
Root cause analysis
A root cause or Ishikawa analysis diagram was used to identify potential factors causing poor TAT performance.[9] Causes were grouped into the following headings: (1) equipment and supplies; (2) environmental; (3) rules, policies, or procedures; and (4) staff or personnel. Focus group meetings were arranged with the laboratory manager and section supervisors to identify causes and to populate the cause-and-effect diagram. A voice recorder was used to create the cause-and-effect diagram using Microsoft Visio (Redmond, Washington, United States).[4]
Results
This laboratory performed 326,081 tests for the 2016/2017 financial period, 341,760 tests for the 2017/2018 financial period, and 399,538 tests for the 2018/2019 financial period. Assuming 24/7 operations, this equates to between 894 and 1,095 tests per day (N. Booplal, 2019, personal communication). Prior to the implementation of the interactive dashboard, weekly TAT data were extracted from the corporate data warehouse that houses LIS data within the National Health Laboratory Service. Weekly Microsoft Excel worksheets were prepared manually and distributed via email prior to the implementation of the interactive dashboard at week 45.
Percentage of within cutoff turnaround time analysis
For the baseline phase, the percentage of TAT within the cutoff fluctuated (range: 10% to 79%) (Figure 1). During the intervention, the TAT range again fluctuated from 59% to 97%. For the post-intervention phase, the percentage of TAT with the cutoff ranged from 89% to 98%. The 90% cutoff was met for 42 consecutive weeks from week 81 to the end of the study period.
|
75th percentile turnaround time analysis
During the baseline phase, the total TAT 75th percentile ranged from four to 20 hours, changing to two to 10 hours for the intervention phase (Figure 2). For the post-intervention phase, the 75th percentile range was two to three hours. For testing TAT, the 75th percentile for the baseline phase ranged from two to 11 hours and changed during the intervention phase to one to six hours. In the post-intervention phase, the range was one to two hours. In the baseline phase, the 75th percentile review TAT ranged from one to 15 hours, compared to one to three hours for the intervention phase. The post-intervention phase reported a 75th percentile review TAT of one hour or less.
|
Root cause analysis
Four major clusters of contributing causes were identified in the root cause analysis, including equipment and supplies; environmental causes; rules, policies, and procedural causes; and staff and personnel factors (Figure 3).
With respect to equipment and supplies, the following causes were shown to have negatively impacted TAT: (1) migration to the new platform (phased approach), (2) difficulties with procurement of laptops to facilitate after-hours off-site authorization, (3) power outages, (4) LIS bandwidth challenges, (5) LIS upgrades, and (6) reagent or stock procurement.
Insufficient air conditioning and water leaks from the ceiling were highlighted as causative environmental factors.
Problems related to rules, policies, and procedures included (1) middleware having to be configured, tested, and amended due to the changes brought about by a phased approach, and (2) a substantial workload being transferred from a nearby laboratory without provision of additional testing or staffing capacity.
For staff and personnel considerations, the following were identified: (1) after-hours authorization delay (by pathologists); (2) industrial action leading to delays; (3) paediatric and low-volume samples requiring manual processing, causing bottlenecks in the workflow; (4) staff constraints (in terms of insufficient staff to manage the benches); (5) additional training of staff being required for new procedures and processes for the platform testing changes implemented; (6) first-line manual sample preparation being needed to enable sample testing prior to full automation; and (7) training for the new platforms provided occurring on-site, while at the same time staff were also required to attend training off-site, leaving benches poorly staffed during training periods.
|
Discussion
In this study, it was hypothesized that the application of appropriate corrective action, guided by an interactive TAT dashboard indicating the proportion of samples within stipulated TAT cutoffs and tail size (outliers), would result in improved performance.[1][10] This was based on the assumption that delivering an interactive TAT dashboard indicating outlier performance on its own would not result in improvement. Good laboratory management and response with appropriate corrective action is the key catalyst to deliver a sustained quality of reporting and ensure the continual TAT improvement of performance over time.[11]
All laboratories typically adhere to a quality management system (QMS) that is used to assess laboratory quality from the pre-analytic phase through the testing and reviewing processes. A QMS is defined as a set of coordinated activities that direct and control a laboratory with regard to quality.[12] All aspects of the laboratory operation, including the organizational structure, processes, and procedures need to be addressed by the QMS to assure quality.[12] Laboratory quality can be defined in terms of accuracy, reliability, and timeliness (i.e., TAT).[12] One of the key practices for continual improvement is the management review meeting, allowing the laboratory an opportunity to review annual performance as set out in the QMS. The management review cycle involves planning, implementing, checking, and acting on a quarterly basis to address shortfalls identified to affect continual improvement.[12]
In this study, we reveal how the introduction of a TAT dashboard enabled senior management of the laboratory in question to assess TAT performance for a particular battery of tests that had not met the stipulated TAT cutoff (greater than 65% of results were outside of the stipulated TAT cutoff). Upon introduction of the dashboard, several areas of concern were immediately identified, including pre-analytical, analytical, and post-analytical factors. With respect to component TAT, assessing specifically the timeframes of "registration to testing" and "testing to release of the report," TAT delays were attributable to delays of review during weeks one to 41, with further delays caused by testing (instrument) interruptions during weeks four and 48. The root cause analysis revealed several contributing factors, categorized as equipment and supplies; environmental; rules, policies, and procedures; and personnel or staffing issues. Specifically, the introduction of an auto-review rule process played an important role in improving TAT cutoff. A similarly placed high-volume core laboratory in Canada also reported that the implementation of a series of lean approaches in their busy laboratory, including automation and auto-review rules, proved effective for more efficiently managing substantial volumes of samples while meeting TAT cutoffs.[13]
Several important lessons learned and documented by the study laboratory could serve as a template for outreach training to help other public sector laboratories achieve similar TAT performance improvements and establish the practices adopted at this site. Firstly, the importance of the need to collate and actively review real-time information about TAT—including components of TAT, in ensuring overall timely reporting in laboratories—was understood and confirmed. Secondly, the value of vertical audits was demonstrated. Vertical audits assisted in understanding what contributed to delayed TAT, and specific focus on outlier samples and vertical audits directed subsequent meaningful corrective action. In line with the requirement of ongoing improvement of service delivery, a weekly "results for action" statement was developed and found to be useful to deliver specific information at the sample or episode level. Such reports, while getting the attention of senior management, could be directed to relevant managers to highlight specific problematic areas and guide the focus of managers’ attention to the investigation of true TAT outliers or exceptions. Such investigation (with solutions) of specifically identified problem areas could yield practical and advantageous outcomes, not only solving the issues at hand, but more widely having a positive impact on overall service delivery improvement.
The final lesson learned revolved around the importance of documenting and following through on corrective actions as part of the QMS. This ensures that corrective actions taken have consequences and are sustained. In the services review presented here, the week-by-week reminders of outlying TAT were a constant cue that solutions implemented had not been effective. Re-evaluation and re-assessment allowed for streamlined processes to be considered when initial corrective actions had failed. Also highlighted was the importance of conducting a root cause analysis using cause-and-effect diagrams, to tease out and understand all aspects of errors and any contributing factors that may lead to delays in TAT. It is also important to point out that although a corrective action may be resolved with a single intervention, more frequently, corrective action proves to be a multi-step process to identify possible solutions and alternatives. Once implemented, these corrective steps require consistent monitoring and evaluation for sustained impact. Here, the information provided by the dashboard offered objective evidence of identified issues that could be documented and presented to senior managers from month to month and at the annual management meeting; that, in due course, enabled corrective action planning and the facilitated, necessary mandates to affect better service.
Past approaches to improving turnaround times
Over the years, there have been multiple approaches to monitoring TAT reporting with the aim of improving TAT and, in turn, patient care. Approaches include identifying outliers, implementing Lean Sigma Six, and performing process mapping.[1][14][15][16][17] One of the earliest approaches described was the identification of TAT outliers.[1] In 2005, Holland et al. reported that the average length of stay in the emergency department across 11 hospitals correlated significantly with the percentage of outliers.[15] In 2007, Hawkins defined outliers as the TAT of samples that exceeded the institution’s agreed TAT cutoffs.[1] Outliers could also be defined as the tail size given the skewed TAT distribution. Therefore, the mean and confidence interval are not appropriate measures for assessing TAT performance. In 2018, Coetzee et al. used the 75th percentile and the percentage of samples within the cutoff TAT to identify outliers at the laboratory and test levels.[10] The development of routine monitoring systems to identify laboratories with a long tail size enabled focused interventions to proactively resolve poor service delivery.[10]
Many laboratories have implemented Lean Six Sigma approaches to improve TAT performance.[13] "Lean" is defined as a continual improvement process consisting of technical tools and management methods.[16] One of the aims of a lean approach is to find and eliminate waste.[16] For example, waste may be introduced by the layout of a laboratory or by poor process design.[16] Long distances between the receiving office and testing laboratory could also, for example, encourage staff to move samples in batches resulting in TAT delays.[16] In 2008, Graban and Padgett reported that the introduction of lean approaches for troponin testing resulted in substantial TAT improvements and averted a proposed point-of-care testing implementation.[16] A 2012 report by Stapleton and Sammond showed how a lean approach implemented over a three-year period in the laboratory resulted in TAT reductions for all emergency tests by implementing both workflow improvements and a dedicated emergency bench.[17]
Another approach to improve TAT was reported by Barakauskas et al. in 2016, involving the use of LIS time stamps, direct observations, and discussions with staff to construct various value stream and process maps for immunosuppressant drug level testing.[14] The value stream map identified process bottlenecks that were addressed.[14] The process map was reported in columns to represent the major groups of personnel and locations from the health care worker to the reference testing laboratory, with the sequence of events and steps involved illustrated in a vertical direction.[14] Bottlenecks were also identified in the process map to plan improvement initiatives, e.g., the use of emergency bags.[14]
Ultimately, the aim of any of the approaches described above is to improve TAT performance and, thus, patient care. Although TAT is especially important for emergency tests that have very short TAT cutoffs, it is equally important to set cutoffs for other, less urgent tests to ensure that respective test results are received by attending physicians in a timely fashion to affect appropriate patient care, an important factor in assuring both the quality of care and the cost-effective use of hospital services.[18] Aside from patient care, TAT delays also have the potential to waste valuable health resources caused by duplicate test requests, thereby increasing public health expenditure.[18] In summary, the multiple approaches to improving TAT performance across all laboratory tests play an important role in improving the quality of patient care.
Application to African contexts
Figure 4 describes an approach that would make it possible for laboratories in low- and middle-income countries to collate the data required to develop the TAT reporting described in our study. In the first instance, laboratories would require a basic LIS that could generate weekly data extracts as described in Figure 4, using open-source database software such as Microsoft SQL Server (Express, Redmond, California, United States).[19] Equally, MySQL[20], Firebird[21], or CUBRID[22] could be deployed to generate the aggregate data described. Training is freely accessible via the internet for these software packages. There are multiple free online courses by providers via platforms such as edX, where one can learn how to both develop and query a structured query language (SQL) database.[23][24] Any of these software packages could be implemented on a local desktop or in a server environment, depending on the data volume, with very basic query tools using SQL commands, making it possible to develop dashboard tools using the step-by-step building blocks approach described in Figure 4.
|
Cross-country collaboration and sharing of resources could play an important role in securing already developed dashboard tools for other African countries. A multi-country approach could reduce overall costs and effort. For example, a single TAT dashboard could be developed for the Southern African Development Community to ensure accessibility and provide scalability. To secure the system and provide confidentiality, each country could have access to their own data using data access privileges. The benefit of this approach is that after the methods, systems, and dashboards are developed, it is easy to extend these developments to other countries with minimal additional cost. The only additional effort required at the country level would be to collate and share the data extracts with the umbrella organizers.
Conclusion
In summary, this study demonstrated that an interactive TAT dashboard that reports appropriate TAT parameters, applied in the context of a QMS and coupled with proactive and diligent management, can accurately identify outliers and lead to appropriate corrective action and sustained timely laboratory reporting.
Limitations
Only LIS data were used for our study. Without a laboratory specimen tracking system, it is not possible to report end-to-end TAT. The implementation of an end-to-end tracking system from the time of venesection to delivery into a laboratory, additionally integrated into a TAT dashboard, could provide valuable supplementary date and time values to allow for an extended TAT efficiency review.
Lessons from the field
Our experiences in the field allow us provide a few lessons learned:
- A weekly interactive TAT dashboard enables reporting of appropriate TAT paramaters and respective outcomes by confirming ongoing quality and timely reporting, as well as identifying outlying TAT that may require appropriate corrective action.
- TAT data can be collected at the laboratory, local network, or national level. A dashboard that includes aggregated and local level data, with a drill-down function, allows hierarchical review of the data, such that both higher-level managers and laboratory managers are able to view the same data, but at different levels appropriate for their respective level of responsibility.
- Continuously collating and analyzing the data and presenting TAT information in a user-friendly, visual dashboard format allows for immediate attention to be focused on outlying sites and areas.
- Visibility and transparency of TAT data and outcomes to all levels of management provide an incentive (with repeated peer or organization pressure, if consistently outside of TAT) to act on poor performance.
- A quality management system requires active input, monitoring, and appropriate action where needed. The presentation of information does not necessarily confer good performance or the meeting of TAT cutoffs. A dashboard, such as that presented here, is merely a tool. Proactive, consistent, and diligent review of TAT data presented in a dashboard is required to facilitate meaningful improvement and corrective action. An auto-review rule implemented for a specific test or battery of tests on the LIS has the potential to reduce TAT by acting to reduce the workload for senior staff through automatic review of predominantly normal results. With the auto-review implemented, senior staff effectively use their time and reserve the resultant review only for samples that fail to meet the auto-review rule, e.g., as with delta check failures.
Acknowledgements
The authors thank area, business, and laboratory managers in Gauteng for their participation and input.
Author contributions
D.K.G. supervised the study by providing leadership and oversight as the project leader. N.C., M.E.E.T. and L.M.C. designed the study, developed the methodology and conducted the research. M.E.E.T. extracted the data. N.C. conducted the data analysis. L.P. provided content for the cause and effect diagram and provided details on the interventions implemented. D.K.G. provided editorial comments and technical input. All authors reviewed the results and contributed to the manuscript development.
Disclaimer
The authors declare that the views expressed in the submitted article are their own and not the official position of any institution or funder.
Competing interests
The authors declare no conflict of interest. The authors further declare that they have no financial or personal relationships that may have inappropriately influenced them in writing this article.
References
- ↑ 1.0 1.1 1.2 1.3 1.4 Hawkins, R.C. (2007). "Laboratory turnaround time". The Clinical Biochemist 28 (4): 179–94. PMC PMC2282400. PMID 18392122. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2282400.
- ↑ 2.0 2.1 2.2 National Health Laboratory Service (2018) (PDF). National Health Laboratory Service Annual Report 2017/18. National Health Laboratory Service. ISBN 9780621457018. https://nationalgovernment.co.za/entity_annual/1714/2018-national-health-laboratory-service-(nhls)-annual-report.pdf.
- ↑ Coetzee, L.M.; Cassim, N.; Tepper, M.E.E. et al. (2018). "The importance of reporting individual weekly laboratory turn-around-time (TAT) to identify outliers and underperformance masked during global annual TAT review". Proceedings of the African Society for Laboratory Medicine Conference 2018. https://www.researchgate.net/publication/329610644. "Poster ID: PS-2.3b-070"
- ↑ 4.0 4.1 4.2 "Apps and services". Microsoft. https://www.microsoft.com/en-za/microsoft-365/products-apps-services. Retrieved 12 March 2019.
- ↑ "Download MicroStrategy Desktop". MicroStrategy. https://www.microstrategy.com/en/get-started/desktop. Retrieved 03 December 2018.
- ↑ Microsoft. "Drill mode in a visual in Power BI". https://docs.microsoft.com/en-us/power-bi/consumer/end-user-drill. Retrieved 12 December 2018.
- ↑ Cassim, N.; Tepper, M.E.; Coetzee, L.M.; Glencross, D.K. (2020). "Timely delivery of laboratory efficiency information, Part I: Developing an interactive turnaround time dashboard at a high-volume laboratory". African Journal of Laboratory Medicine 9 (2): a947. doi:10.4102/ajlm.v9i2.947. PMC PMC7203318. PMID 32391244. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7203318.
- ↑ 8.0 8.1 Khan, K.. "Root Cause Analysis (RCA) of Prolonged Laboratory Turnaround Time in a Tertiary Care Set Up". Journal of Clinical and Diagnostic Research 8 (4): FC05–FC08. doi:10.7860/JCDR/2014/7269.4255. PMC PMC4064846. PMID 24959450. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4064846.
- ↑ Ishikawa, K. (1976). Guide to Quality Control (2nd Revised ed.). Asian Productivity Organization. ISBN 9283310365. https://archive.org/details/guidetoqualityco00ishi/page/n7/mode/2up.
- ↑ 10.0 10.1 10.2 Coetzee, L.-M.; Cassim, N.; Glencross, D.K. (2018). "Using laboratory data to categorise CD4 laboratory turn-around-time performance across a national programme". African Journal of Laboratory Medicine 7 (1): 665. doi:10.4102/ajlm.v7i1.665. PMC PMC6111574. PMID 30167387. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6111574.
- ↑ Ezzelle, J.; Rodriguez-Chavez, I.R.; Darden, J.M. et al. (2008). "Guidelines on good clinical laboratory practice: bridging operations between research and clinical research laboratories". Journal of Pharmaceutical and Biomedical Analysis 46 (1): 18–29. doi:10.1016/j.jpba.2007.10.010. PMC PMC2213906. PMID 18037599. https://www.ncbi.nlm.nih.gov/pmc/articles/PMC2213906.
- ↑ 12.0 12.1 12.2 12.3 World Health Organization (2011) (PDF). Laboratory Quality Management System Handbook. World Health Organization. ISBN 9789241548274. https://www.who.int/ihr/publications/lqms_en.pdf.
- ↑ 13.0 13.1 Lou, A.H.; Elnenaei, M.O.; Sadek, I. et al. (2017). "Multiple pre- and post-analytical lean approaches to the improvement of the laboratory turnaround time in a large core laboratory". Clinical Biochemistry 50 (15): 864–69. doi:10.1016/j.clinbiochem.2017.04.019. PMID 28457964.
- ↑ 14.0 14.1 14.2 14.3 14.4 Barakauskas, V.E.; Bradshaw, T.A.; Smith, L.D. et al. (2016). "Process Optimization to Improve Immunosuppressant Drug Testing Turnaround Time". American Journal of Clinical Pathology 146 (2): 182–90. doi:10.1093/ajcp/aqw087. PMID 27453440.
- ↑ 15.0 15.1 Holland, L.L.; Smith, L.L.; Blick, K.E. (2005). "Reducing laboratory turnaround time outliers can reduce emergency department patient length of stay: An 11-hospital study". American Journal of Clinical Pathology 124 (5): 672–4. doi:10.1309/E9QP-VQ6G-2FBV-MJ3B. PMID 16203280.
- ↑ 16.0 16.1 16.2 16.3 16.4 16.5 Graban, M.; Padgett, S. (2008). "Lean Laboratories: Competing with Methods From Toyota". Laboratory Medicine 39 (11): 645–48. doi:10.1309/LMX0LEMR7R0USKUM.
- ↑ 17.0 17.1 Stapleton, K.; Sammond, D. (2012). "Improved Laboratory Stat Test Turnaround Time Using Lean Six Sigma". American Journal of Clinical Pathology 138 (Suppl. 2): A184. doi:10.1093/ajcp/138.suppl2.36.
- ↑ 18.0 18.1 Winkelman, J.W.; Tanasijevic, M.J.; Wybenga, D.R. et al. (1997). "How fast is fast enough for clinical laboratory turnaround time? Measurement of the interval between result entry and inquiries for reports". American Journal of Clinical Pathology 108 (4): 400–5. doi:10.1093/ajcp/108.4.400. PMID 9322592.
- ↑ Microsoft. "SQL Server 2019". https://www.microsoft.com/en-us/sql-server/sql-server-2019. Retrieved 10 April 2019.
- ↑ Oracle Corporation. "MySQL Community Edition". https://www.mysql.com/products/community/. Retrieved 03 February 2019.
- ↑ Firebird Project. "Firebird RDBMS". https://firebirdsql.org/en/firebird-rdbms/. Retrieved 10 April 2019.
- ↑ CUBRID Foundation. "CUBRID". https://www.cubrid.org/. Retrieved 10 April 2019.
- ↑ Microsoft. "Querying Data with Transact-SQL". edX. https://www.edx.org/course/querying-data-with-transact-sql-2. Retrieved 03 April 2019.
- ↑ Microsoft. "Developing SQL Databases". edX. Archived from the original on 20 May 2020. https://web.archive.org/web/20200502074237/http://www.edx.org/course/developing-sql-databases. Retrieved 03 April 2019.
Notes
This presentation is faithful to the original, with only a few minor changes to presentation. Grammar was cleaned up for smoother reading. In some cases important information was missing from the references, and that information was added. The original citation number two (2017-2018 NHLS Annual Report) was dead; an alternately hosted version was found and used for this version. The original cites Wikipedia concerning the Ishikawa diagram; as using Wikipedia as a citation is generally frowned upon, a substitute citation for Ishikawa's original Guide to Quality Control was used for this version. The original article accidentally mixed up citations 19 and 20; this was corrected for this version. The citation URL for the SQL Databases edX course is dead; an archived version of the URL is used for this version. The original article used an image for lessons learned in the field; this version skips the image and replaces it with the image text.